SVR-3P Series
Servo Electronic
Voltage Stabilisers & Power Line Conditioners
Three Phase
6 to 120 kVA
Home » Servo Voltage Stabilizers » SVR-3P Series
SVR Series - Three-Phase
Servo Electronic AC Voltage Stabilizers - 6 to 120kVA
With over 30 years of unrivalled experience, gained in some of the world’s most challenging and demanding power environments, our long-standing Servo Electronic (SES) Stabilisers are able to handle the widest of input voltage windows (up to ±40%).
Now Digitally remastered to meet the demands of today’s modern age, our latest generation SVR Series three-phase offerings include as standard many advanced protection features – usually only available from others as additional expensive add-on options!
For less prevalent situations, where electrical noise is also an issue on-site, most models are also available as Power Line Conditioners offering an enhanced level of Transient Voltage Surge & Spike Suppression (TVSS) protection and delivering the added benefit of filtering out any electrical noise and interference present on the incoming utility supply – ensuring what is commonly referred to as a ‘CLEAN’ supply
Three Phase 4 Wire and 3 Wire (without neutral) models are offered in 16 different power ratings from 6 to 120 kVA, being able to accommodate situations where the incoming nominal utility supply is either 380 to 415V (H/HD Series), 190 to 240V (LY/LD Series), or 440 to 480V (HX/HXD Series).
To learn more about the range of Three-Phase SVR Voltage Stabilisers and Power Conditioners available from Ashley-Edison (UK), please check out the following listings, or download the brochure below:-

Standard Features include:
![]() | Automatic Step-Less Voltage Stabilisation / Regulation |
![]() | Cost-Efficient Servo Electronic Digitally Enhanced Design |
![]() | Wide Permissible Input Voltage Window (up to ±40%) |
![]() | Precise Output Voltage Accuracy (Adjustable ±1% to ±5%) |
![]() | Independent Phase Control |
![]() | Extremely Low Maintenance |
![]() | TVSS – Transient Voltage Surge & Spike Suppression Protection |
![]() | Inbuilt High Overload Capability |
![]() | Over / Low Voltage Protection |
![]() | Phase Failure Protection |
![]() | Start Up Load Protection |
![]() | Class II SPD – Lightning Surge Arrestor |
![]() | LCD Digital Monitoring & Display Panel – Input & Output Voltage Metering – Output Current Metering – Operational Status & Alarm Conditions |
![]() | Input Circuit Breaker |
![]() | Output Isolation |
![]() | Manual Bypass Switch (with mechanical interlocking) |
![]() | Hard Wire Input & Output (with Bottom Cable Entry) |
![]() | RS/485 Interface |
![]() | Freestanding IP20 Indoor Enclosure |
![]() | Built to comply with leading International Standards |
![]() | Supplied with a 2 Year / 24 Months Warranty |
Optional Features available include:
![]() | Outdoor IP54 Enclosure (-IP54) Stabiliser presented in endurable IP54 (BS / EN 60529) / NEMA 3 free-standing steel cubicles suitable for external use, or more challenging internal environments |
![]() | Input Isolating Transformer (-PC) Through the integration of a shielded isolation transformer, provides enhanced spike & electrical noise (Common Mode: 120db @ 100khz & Normal Mode Noise: 60db @ 100khz) suppression and neutral ground bonding. Delivers what is commonly referred to as a ‘CLEAN’ supply |
![]() | AquaStop (-AS) PCB protective coating offering protection against damp and moisture ingress |
![]() | Additional Digital Metering (-ADM) Additional Digital Metering for Frequency & Power Factor |
![]() | 4 Pole Switches / Breakers (-FP) As standard ESR Stabilisers utilise 3 Pole Switches / Breakers. As an option 4 Pole alternatives can be supplied. |
![]() | Alternative Paint Colour (-RAL) Alternative Paint Colour Finish – customer to specify |
![]() | Output Circuit Breaker (-OCB) Replacement of the Output Contactor with an Output Circuit Breaker |
SELECT | Permissible Input Voltage Window Options (–S*):
Swing Options | Nominal Voltage | Max Model Rating | |||
380/220V | 400/230V | 415/240V | |||
S15 | ±15% | 323 to 437V / 187 to 253V | 340 to 460V / 196 to 265V | 353 to 477V / 204 to 276V | 120 kVA |
S20 | ±20% | 304 to 458V / 176 to 264V | 320 to 480V / 184 to 276V | 332 to 498V / 192 to 288V | 120 kVA |
S25 | ±25% | 285 to 475V / 165 to 275V | 300 to 500V / 173 to 288V | 311 to 519V / 180 to 300V | 100 kVA |
S30 | ±30% | 266 to 494V / 154 to 286V | 280 to 520V / 161 to 299V | 291 to 540V / 168 to 312V | 80 kVA |
S35 | ±35% | 247 to 513V / 143 to 297V | 260 to 540V / 150 to 311V | 270 to 560V / 156 to 329V | 75 kVA |
S40 | ±40% | 228 to 532V / 132 to 308V | 240 to 560V / 136 to 322V | 249 to 581V / 144 to 336 | 75 kVA |
SELECT | Required Power Rating:
Power Rating (kVA) | Max Rating (Amps per Phase) | SVR-H-3P-T1F Model No (S*=Add Swing Option No) | ||
380/220V | 400/230V | 415/240V | ||
6 kVA | 9.1A | 8.7A | 8.3A | SVR-6H-3P-T1F-S* |
10 kVA | 15.2A | 14.4 | 13.9A | SVR-10H-3P-T1F-S* |
15 kVA | 22A | 21A | 20A | SVR-15H-3P-T1F-S* |
20 kVA | 30A | 28A | 27A | SVR-20H-3P-T1F-S* |
25 kVA | 38A | 36A | 34A | SVR-25H-3P-T1F-S* |
30 kVA | 45A | 43A | 41A | SVR-30H-3P-T1F-S* |
35 kVA | 53A | 50A | 48A | SVR-35H-3P-T1F-S* |
40 kVA | 60A | 57A | 55A | SVR-40H-3P-T1F-S* |
45 kVA | 68A | 64A | 62A | SVR-45H-3P-T1F-S* |
50 kVA | 75A | 72A | 69A | SVR-50H-3P-T1F-S* |
55 kVA | 83A | 79A | 76A | SVR-55H-3P-T1F-S* |
60 kVA | 91A | 86A | 83A | SVR-60H-3P-T1F-S* |
75 kVA | 113A | 108A | 104A | SVR-75H-3P-T1F-S* |
80 kVA | 121A | 115A | 113A | SVR-80H-3P-T1F-S* |
90 kVA | 136A | 129A | 125A | SVR-90H-3P-T1F-S* |
100 kVA | 151A | 144A | 139A | SVR-100H-3P-T1F-S* |
120 kVA | 182A | 173A | 166A | SVR-120H-3P-T1F-S* |
Note: All SVR-3P-T1F Stabilisers are designed to support the full load at minimum input volts and maximum ambient temperature.
SELECT | Permissible Input Voltage Window Options (–S*):
Swing Options | Nominal Voltage | Max Model Rating | ||||
190/110V | 200/115V | 208/120V | 220/127V | |||
S15 | ±15% | 162 to 219V / 94 to 127V | 170 to 230V / 98 to 132V | 177 to 239V / 102 to 138V | 187 to 253V / 106 to 146V | 100 kVA |
S20 | ±20% | 152 to 228V / 88 to 132V | 160 to 240V / 92 to 138V | 166 to 250V / 96 to 144V | 176 to 264V / 102 to 152V | 60 kVA |
S25 | ±25% | 143 to 238V / 83 to 138V | 150 to 250V / 86 to 144V | 156 to 260V / 90 to 150V | 165 to 275V / 95 to 159V | 45 kVA |
S30 | ±30% | 133 to 247V / 77 to 143V | 140 to 260V / 81 to 150V | 146 to 270V / 84 to 156V | 154 to 286V / 89 to 165V | 45 kVA |
SELECT | Required Power Rating:
Power Rating (kVA) | Max Rating (Amps per Phase) | SVR-LY-3P-T1F Model No (S*=Add Swing Option No) | |||
190/110V | 200/115V | 208/120V | 220/127V | ||
6 kVA | 18.2A | 17.3A | 16.6A | 15.7A | SVR-6LY-3P-T1F-S* |
10 kVA | 30.4A | 28.9A | 27.7A | 26.2A | SVR-10LY-3P-T1F-S* |
15 kVA | 45A | 43A | 41A | 39A | SVR-15LY-3P-T1F-S* |
20 kVA | 60A | 57A | 55A | 52A | SVR-20LY-3P-T1F-S* |
25 kVA | 75A | 72A | 69A | 65A | SVR-25LY-3P-T1F-S* |
30 kVA | 91A | 86A | 83A | 78A | SVR-30LY-3P-T1F-S* |
35 kVA | 106A | 101A | 97A | 91A | SVR-35LY-3P-T1F-S* |
40 kVA | 121A | 115A | 111A | 104A | SVR-40LY-3P-T1F-S* |
45 kVA | 136A | 129A | 124A | 118A | SVR-45LY-3P-T1F-S* |
50 kVA | 151A | 144A | 138A | 131A | SVR-50LY-3P-T1F-S* |
55 kVA | 167A | 158A | 152A | 144A | SVR-55LY-3P-T1F-S* |
60 kVA | 182A | 173A | 166A | 157A | SVR-60LY-3P-T1F-S* |
75 kVA | 227A | 216A | 208A | 196A | SVR-75LY-3P-T1F-S* |
80 kVA | 243A | 230A | 222A | 209A | SVR-80LY-3P-T1F-S* |
90 kVA | 273A | 259A | 249A | 236A | SVR-90LY-3P-T1F-S* |
100 kVA | 303A | 288A | 277A | 262A | SVR-100LY-3P-T1F-S* |
Note:
All SVR Stabilisers are designed to support the full load at minimum input volts and maximum ambient temperature.
SELECT | Permissible Input Voltage Window Options (–S*):
Swing Options | Nominal Voltage | Max Model Rating | |||
440/256V | 460/265V | 480/277V | |||
S15 | ±15% | 374 to 506V / 216 to 292V | 391 to 529V / 225 to 305V | 408 to 552V / 235 to 319V | 100 kVA |
S20 | ±20% | 352 to 528V / 203 to 305V | 368 to 552V / 212 to 318V | 384 to 576V / 222 to 332V | 80 kVA |
S25 | ±25% | 330 to 550V / 191 to 318V | 345 to 575V / 199 to 331V | 360 to 600V / 208 to 346V | 75 kVA |
S30 | ±30% | 308 to 572V / 178 to 330V | 322 to 598V / 186 to 345V | 336 to 624V / 194 to 360V | 60 kVA |
SELECT | Required Power Rating:
Power Rating (kVA) | Max Rating (Amps per Phase) | SVR-HX-3P-T1F Model No (S*=Add Swing Option No) | ||
440/256V | 460/265V | 480/277V | ||
6 kVA | 7.9A | 7.5A | 7.2A | SVR-6HX-3P-T1F-S* |
10 kVA | 13.1A | 12.5A | 12.0A | SVR-10HX-3P-T1F-S* |
15 kVA | 19A | 18A | 18A | SVR-15HX-3P-T1F-S* |
20 kVA | 26A | 25A | 24A | SVR-20HX-3P-T1F-S* |
25 kVA | 32A | 31A | 30A | SVR-25HX-3P-T1F-S* |
30 kVA | 39A | 37A | 36A | SVR-30HX-3P-T1F-S* |
35 kVA | 45A | 43A | 42A | SVR-35HX-3P-T1F-S* |
40 kVA | 52A | 50A | 48A | SVR-40HX-3P-T1F-S* |
45 kVA | 59A | 56A | 54A | SVR-45HX-3P-T1F-S* |
50 kVA | 65A | 62A | 60A | SVR-50HX-3P-T1F-S* |
55 kVA | 72A | 69A | 66A | SVR-55HX-3P-T1F-S* |
60 kVA | 78A | 75A | 72A | SVR-60HX-3P-T1F-S* |
75 kVA | 98A | 94A | 90A | SVR-75HX-3P-T1F-S* |
80 kVA | 104A | 100A | 96A | SVR-80HX-3P-T1F-S* |
90 kVA | 118A | 112A | 108A | SVR-90HX-3P-T1F-S* |
100 kVA | 131A | 125A | 120A | SVR-100HX-3P-T1F-S* |
Note: All SVR Stabilisers are designed to support the full load at minimum input volts and maximum ambient temperature.
SELECT | Permissible Input Voltage Window Options (–S*):
Swing Options | Nominal Voltage | Max Model Rating | |||
380V | 400V | 415V | |||
S15 | ±15% | 323 to 437V | 340 to 460V | 353 to 477V | 120 kVA |
S20 | ±20% | 304 to 458V | 320 to 480V | 332 to 498V | 120 kVA |
S25 | ±25% | 285 to 475V | 300 to 500V | 311 to 519V | 100 kVA |
S30 | ±30% | 266 to 494V | 280 to 520V | 291 to 540V | 80 kVA |
S35 | ±35% | 247 to 513V | 260 to 540V | 270 to 560V | 75 kVA |
S40 | ±40% | 228 to 532V | 240 to 560V | 249 to 581V | 75 kVA |
SELECT | Required Power Rating:
Power Rating (kVA) | Max Rating (Amps per Phase) | SVR-HD-3P-T1F Model No (S*=Add Swing Option No) | ||
380V | 400V | 415V | ||
6 kVA | 9.1A | 8.7A | 8.3A | SVR-6HD-3P-T1F-S* |
10 kVA | 15.2A | 14.4 | 13.9A | SVR-10HD-3P-T1F-S* |
15 kVA | 22A | 21A | 20A | SVR-15HD-3P-T1F-S* |
20 kVA | 30A | 28A | 27A | SVR-20HD-3P-T1F-S* |
25 kVA | 38A | 36A | 34A | SVR-25HD-3P-T1F-S* |
30 kVA | 45A | 43A | 41A | SVR-30HD-3P-T1F-S* |
35 kVA | 53A | 50A | 48A | SVR-35HD-3P-T1F-S* |
40 kVA | 60A | 57A | 55A | SVR-40HD-3P-T1F-S* |
45 kVA | 68A | 64A | 62A | SVR-45HD-3P-T1F-S* |
50 kVA | 75A | 72A | 69A | SVR-50HD-3P-T1F-S* |
55 kVA | 83A | 79A | 76A | SVR-55HD-3P-T1F-S* |
60 kVA | 91A | 86A | 83A | SVR-60HD-3P-T1F-S* |
75 kVA | 113A | 108A | 104A | SVR-75HD-3P-T1F-S* |
80 kVA | 121A | 115A | 113A | SVR-80HD-3P-T1F-S* |
90 kVA | 136A | 129A | 125A | SVR-90HD-3P-T1F-S* |
100 kVA | 151A | 144A | 139A | SVR-100HD-3P-T1F-S* |
120 kVA | 182A | 173A | 166A | SVR-120HD-3P-T1F-S* |
Note:
1: All SVR Stabilisers are designed to support the full load at minimum input volts and maximum ambient temperature.
2: Where the nominal utility supply is 3 Wire (Without Neutral) in nature, models are also available, on specific quotations, offering a 4 Wire (with Neutral) Output.
SELECT | Permissible Input Voltage Window Options (–S*):
Swing Options | Nominal Voltage | Max Model Rating | |||||
190V | 200V | 208V | 220V | 240V | |||
S15 | ±15% | 162 to 219V | 170 to 230V | 177 to 239V | 187 to 253V | 204 to 276V | 100 kVA |
S20 | ±20% | 152 to 228V | 160 to 240V | 166 to 250V | 176 to 264V | 192 to 288V | 60 kVA |
S25 | ±25% | 143 to 238V | 150 to 250V | 156 to 260V | 165 to 275V | 180 to 300V | 45 kVA |
S30 | ±30% | 133 to 247V | 140 to 260V | 146 to 270V | 154 to 286V | 168 to 312V | 45 kVA |
SELECT | Required Power Rating:
Power Rating (kVA) | Max Rating (Amps per Phase) | SVR-LD-3P-T1F Model No (S*=Add Swing Option No) | ||||
190/V | 200V | 208V | 220v | 240V | ||
6 kVA | 18.2A | 17.3A | 16.6A | 15.7A | 14.4A | SVR-6LD-3P-T1F-S* |
10 kVA | 30.4A | 28.9A | 27.7A | 26.2A | 24.0A | SVR-10LD-3P-T1F-S* |
15 kVA | 45A | 43A | 41A | 39A | 36.1A | SVR-15LD-3P-T1F-S* |
20 kVA | 60A | 57A | 55A | 52A | 48A | SVR-20LD-3P-T1F-S* |
25 kVA | 75A | 72A | 69A | 65A | 60A | SVR-25LD-3P-T1F-S* |
30 kVA | 91A | 86A | 83A | 78A | 72A | SVR-30LD-3P-T1F-S* |
35 kVA | 106A | 101A | 97A | 91A | 84A | SVR-35LD-3P-T1F-S* |
40 kVA | 121A | 115A | 111A | 104A | 96A | SVR-40LD-3P-T1F-S* |
45 kVA | 136A | 129A | 124A | 118A | 108A | SVR-45LD-3P-T1F-S* |
50 kVA | 151A | 144A | 138A | 131A | 120A | SVR-50LD-3P-T1F-S* |
55 kVA | 167A | 158A | 152A | 144A | 132A | SVR-55LD-3P-T1F-S* |
60 kVA | 182A | 173A | 166A | 157A | 144A | SVR-60LD-3P-T1F-S* |
75 kVA | 227A | 216A | 208A | 196A | 180A | SVR-75LD-3P-T1F-S* |
80 kVA | 243A | 230A | 222A | 209A | 192A | SVR-80LD-3P-T1F-S* |
90 kVA | 273A | 259A | 249A | 236A | 216A | SVR-90LD-3P-T1F-S* |
100 kVA | 303A | 288A | 277A | 262A | 240A | SVR-100LD-3P-T1F-S* |
Note:
1: All SVR Stabilisers are designed to support the full load at minimum input volts and maximum ambient temperature.
2: Where the nominal utility supply is 3 Wire (Without Neutral) in nature, models are also available, on specific quotations, offering a 4 Wire (with Neutral) Output.
SELECT | Permissible Input Voltage Window Options (–S*):
Swing Options | Nominal Voltage | Max Model Rating | |||
440V | 460V | 480V | |||
S15 | ±15% | 374 to 506V | 391 to 529V | 408 to 552V | 100 kVA |
S20 | ±20% | 352 to 528V | 368 to 552V | 384 to 576V | 80 kVA |
S25 | ±25% | 330 to 550V | 345 to 575V | 360 to 600V | 75 kVA |
S30 | ±30% | 308 to 572V | 322 to 598V | 336 to 624V | 60 kVA |
SELECT | Required Power Rating:
Power Rating (kVA) | Max Rating (Amps per Phase) | SVR-HXD-3P-T1F Model No (S*=Add Swing Option No) | ||
440V | 460V | 480V | ||
6 kVA | 7.9A | 7.5A | 7.2A | SVR-6HXD-3P-T1F-S* |
10 kVA | 13.1A | 12.5A | 12.0A | SVR-10HXD-3P-T1F-S* |
15 kVA | 19A | 18A | 18A | SVR-15HXD-3P-T1F-S* |
20 kVA | 26A | 25A | 24A | SVR-20HXD-3P-T1F-S* |
25 kVA | 32A | 31A | 30A | SVR-25HXD-3P-T1F-S* |
30 kVA | 39A | 37A | 36A | SVR-30HXD-3P-T1F-S* |
35 kVA | 45A | 43A | 42A | SVR-35HXD-3P-T1F-S* |
40 kVA | 52A | 50A | 48A | SVR-40HXD-3P-T1F-S* |
45 kVA | 59A | 56A | 54A | SVR-45HXD-3P-T1F-S* |
50 kVA | 65A | 62A | 60A | SVR-50HXD-3P-T1F-S* |
55 kVA | 72A | 69A | 66A | SVR-55HXD-3P-T1F-S* |
60 kVA | 78A | 75A | 72A | SVR-60HXD-3P-T1F-S* |
75 kVA | 98A | 94A | 90A | SVR-75HXD-3P-T1F-S* |
80 kVA | 104A | 100A | 96A | SVR-80HXD-3P-T1F-S* |
90 kVA | 118A | 112A | 108A | SVR-90HXD-3P-T1F-S* |
100 kVA | 131A | 125A | 120A | SVR-100HXD-3P-T1F-S* |
Note:
1: All SVR Stabilisers are designed to support the full load at minimum input volts and maximum ambient temperature.
2: Where the nominal utility supply is 3 Wire (Without Neutral) in nature, models are also available, on specific quotations, offering a 4 Wire (with Neutral) Output.
General Technical Specification
General: | ||
– Design Topology: | Servo Electronic – Variable Transformer controlled | |
– Phase: | H, LY & HX Series | Three Phase, 4 Wire (3P+N+G/E) |
HD, LD & HXD Series | Three Phase, 3 Wire (3P+G/E) – NO Neutral | |
– Power Ratings: | 17 Model Ratings- 6kVA, 10kVA, 15kVA, 20kVA, 25kVA, 30kVA, 35kVA, 40kVA, 45kVA, 50kVA, 55kVA, 60kVA, 75kVA, 80kVA, 90kVA, 100kVA, & 120kVA | |
– Frequency: | 50 / 60Hz (35 to 63Hz) | |
– Power Factor: | The Power Factor has no effect on performance providing the stabilizer is being used within its rated capacity | |
Input: | ||
– Nominal Voltage: | H (HD) Series | 380/220V -400/230V – 415/240V, Three Phase, 4 Wire (HD – 3 Wire) |
LY (LD) Series | 190/100V – 200/115V – 208/120V – 220/127V, Three Phase, 4 Wire (LD – 3 Wire) | |
HX (HXD) Series | 440/254V – 460/265V – 480/277V, Three Phase, 4 Wire (HXD – 3 Wire) | |
– Input Voltage Window Options (S*): | S15 | Nominal Voltage ±15% (All Series) |
S20 | Nominal Voltage ±20% (All Series) | |
S25 | Nominal Voltage ±25% (All Series) | |
S30 | Nominal Voltage ±30% (All Series) | |
S35 | Nominal Voltage ±35% (H & HD Series Only) | |
S40 | Nominal Voltage ±40% (H & HD Series Only) | |
Output: | ||
– Voltage: | H (HD) Series | 380V -400V – 415V, Three Phase, 4 Wire (HD – 3 Wire) |
LY (LD) Series | 190V – 200V – 208V – 220V – 240V, Three Phase, 4 Wire (LD – 3 Wire) | |
HX (HXD) Series | 440V – 460V – 480V, Three Phase, 4 Wire (HXD – 3 Wire) | |
– Voltage Accuracy: | ±3% (Default) – adjustable ±1% to ±5% | |
– Correction Time: | Typically a 10% supply variation will be corrected to within 2.5% in 0.6 seconds | |
– Efficiency: | ≥98% | |
– Independent Phase Control: | Maintains each phase voltage stable irrespective of load unbalance, even in situations where a 100% load unbalance may exist. | |
– Overload Ratings: | 10 x max. current rating for 2 seconds 3 x max. current rating for 1 minute 2 x max. current rating for 2 minutes | |
Display Panel – Metering, Alerts & Communication: | ||
– Digital Metering: | Input Volts, Output Volts, and Load | |
– Status Indication: | Overload, Over-Volts, Under-Volts, & Fuse Blown | |
– Interface: | RS-485 – DB9 Pin Style Port | |
– Display Settable Parameters: | Output Voltage, Output Voltage Accuracy, Correction Time, Over-Voltage Level, Under-Voltage Level & Over Current Limit | |
Protection Features: | ||
– Surge Protection: | TVSS – Protects loads against high-energy Spikes and Transient Voltages | |
– Lightning Surge Protection: | Class II SPD – protection against extremely high voltage surges and transients caused by lightning strikes on the utility mains supply line | |
– Input Breaker: | Standard on all models – delivers over current input protection | |
– Manual Bypass: | ‘Break Before Make’ bypass facility (with mechanical interlocking) offering the ability to route the supply feed to bypass the stabiliser/conditioner. Useful when performing deep maintenance on the system, or in the highly unlikely event of a system malfunction. | |
– Output Isolation: | Automatic disconnection of the load in the event of a fault condition being detected | |
– Phase Failure: | Any failure of phases will be immediately detected and will instigate an automatic load isolation | |
– Over & Under Volts | Ability to configure the voltage stabiliser/power conditioner, to shut down in the event of the incoming voltage supply going outside the specified input voltage window | |
Environmental: | ||
– Operating Temperature Range: | -15°C to +45°C Derate by 2% for each additional °C up to max 60°C | |
– Maximum Altitude: | 1000 meters (derate by 2.5% per additional 500 meters) | |
– Relative Humidity: | Suitable for indoor tropical use – 0 to 95% (non-condensing) | |
– Harmonic Distortion: | None introduced | |
– Audible Noise: | @ 1 meter 50 to 65 dBA (dependent on model rating) | |
Physical: | ||
– Power Connections: | Hardwire Input & Output with bottom cable entry (Option – top and side cable entry) | |
– Construction: | Enclosures to IP20 / NEMA 1 Style – BS EN 60529 (Option – Outdoor IP54/NEMA 3 Style) | |
– Paint Colour: | RAL 1013 (Oyster White – Epoxy Powder Coating) – Other paint colours on specific request | |
– Dimensions & Weights: | Dependent on model rating and configuration Sizes and weights available on individual request | |
Certification & Conformance: | ||
– EMC Conformance: | BS EN 55022 and relevant parts of BS EN 61000 | |
– CE Certification: | CE Marked – 2014/30/EU (The EMC Directive) and 2014/35/EU (The Low Voltage Directive) | |
– Warranty: | 2 Years / 24 Months from date of supply | |
Optional Add-Ons: | ||
– Outdoor IP54 Enclosure (-IP54) | Stabiliser presented in endurable IP54 (BS / EN 60529) / NEMA 3 free-standing steel cubicles suitable for external use, or more challenging internal environments | |
– Input Isolating Transformer (-PC) | Through the integration of a shielded isolation transformer, provides enhanced spike & electrical noise (Common Mode: 120db @ 100khz & Normal Mode Noise: 60db @ 100khz) suppression and neutral ground bonding. Delivers what is commonly referred to as a ‘CLEAN’ supply | |
– AquaStop (-AS) | PCB protective coating offering protection against damp and moisture ingress | |
– Additional Digital Metering (-ADM) | Additional Digital Metering for Frequency & Power Factor | |
– 4 Pole Switches / Breakers (-FP) | As standard ESR Stabilisers utilise 3 Pole Switches / Breakers. As an option 4 Pole alternatives can be supplied. | |
– Alternative Paint Colour (-RAL) | Alternative Paint Colour Finish – customer to specify | |
– Output Circuit Breaker (-OCB) | Replacement of the Output Contactor with an Output Circuit Breaker |
Note:
1: All SVR Stabilisers are designed to support the full load at minimum input volts and maximum ambient temperature.
2: Where the nominal utility supply is 3 Wire (Without Neutral) in nature, models are also available, on specific quotations, offering a 4 Wire (with Neutral) Output.
Sales & Support
4 wire systems – With Neutral
![]() | H Series [380/220V, 400/230V, or 415/240V Models] |
![]() | LY Series [190/100V, 200/110V, 208/120V, or 220/127V Models] |
![]() | HX Series [440/256V, 460/265V or 480/277V Models] |
![]() | Guide Specification |
![]() | Operator / User Manual |
3 wire systems – Without Neutral
![]() | HD Series [380V, 400V or 415V Models] |
![]() | LD Series [190V, 200V, 208V, 220V or 240V Models] |
![]() | HXD Series [440V, 460V or 480V Models] |
![]() | Guide Specification |
![]() | Operator / User Manual |
CE Certification
SVR Series Three Phase Servo Electronic AC Voltage Stabilisers / Conditioners comply with the relevant European Union (EU) health, safety and environmental protection directives and regulations and are duly CE marked.
Ashley-Edison Declaration
![]() | Machine (MD) Directive – 2006/42/EC – in force from December 2009 EMC Directive – 2014/30/EU – in force from April 2016 Low Voltage Directive – 2014/35/EU – in force from April 2016 |
Independent 3rd party verification certificate
![]() | Machine (MD) Directive – 2006/42/EC – in force from December 2009 |
If you do not find the Voltage Stabiliser or Power Line Conditioner that meets your application’s exact needs, please contact us with your specific detailed requirements.