SVR Series - Single-Phase
Servo Electronic AC Voltage Stabilizers - 6 to 50kVA
Suitable for 95% of all applications, SVR Servo Electronic (SES) stabilisers not only guard against voltage fluctuations they also offer protection against all too common harmful high-energy surges, transients and voltage spikes.
Digitally remastered to meet the demands of today’s modern age, our latest generation SVR Series models deliver a step less automated regulation of the incoming utility mains supply.
Offered as two ranges, in ratings from 6 to over 50kVA, H Series models support international 220 to 240 Volt mains supplies and L Series models support US-Style utility supplies of 100 to 127 volts.
To learn more about the range of Single-Phase SVR Voltage Stabilisers and Power Conditioners available from Ashley-Edison (UK), please check out the following listings, or download the brochure below:
Standard Features include:
Automatic Step-Less Voltage Stabilisation / Regulation | |
Cost-Efficient Servo Electronic Digitally Enhanced Design | |
Wide Permissible Input Voltage Window (up to ±40%) | |
Precise Output Voltage Accuracy (Adjustable ±1% to ±5%) | |
Extremely Low Maintenance | |
TVSS – Transient Voltage Surge & Spike Suppression Protection | |
Inbuilt High Overload Capability | |
Over / Low Voltage Protection | |
Start Up Load Protection | |
Class II SPD – Lightning Surge Arrestor | |
LCD Digital Monitoring & Display Panel
| |
Input Circuit Breaker | |
Output Isolation | |
Manual Bypass Switch (with mechanical interlocking) | |
Hard Wire Input & Output (with Bottom Cable Entry) | |
RS/485 Interface | |
Freestanding IP20 Indoor Enclosure | |
Built to comply with leading International Standards | |
Supplied with a 2 Year / 24 Months Warranty |
Optional Features available include:
Output Circuit Breaker (-OCB) | |
Isolation Transformer (-PC) delivering what is commonly referred to as a Clean Supply (Power Conditioner) | |
IP54 / NEMA 3 Style Outdoor Enclosure (-IP54) for external use or more challenging internal environments |
SELECT | Permissible Input Voltage Window Options (–S*):
Swing Options | Nominal Voltage | Max Model Rating | |||
220V | 230V | 240V | |||
S15 | ±15% | 187 to 253V | 196 to 265V | 204 to 276V | 50 kVA |
S20 | ±20% | 176 to 264V | 184 to 276V | 192 to 288V | 50 kVA |
S25 | ±25% | 165 to 275V | 173 to 288V | 180 to 300V | 40 kVA |
S30 | ±30% | 154 to 286V | 161 to 299V | 168 to 312V | 30 kVA |
S35 | ±35% | 143 to 297V | 150 to 311V | 156 to 329V | 20 kVA |
S40 | ±40% | 132 to 308V | 136 to 322V | 144 to 336V | 20 kVA |
SELECT | Required Power Rating:
Power Rating (kVA) | Max Rating (Amps per Phase) | SVR-H-T1F Model No (S*=Add Swing Option No) | ||
220V | 230V | 240V | ||
6 kVA | 27.3A | 26.1A | 25.0A | SVR-6H-T1F-S* |
8 kVA | 36.4A | 34.8 | 33.3A | SVR-8H-T1F-S* |
10 kVA | 45.5A | 43.5A | 41.7A | SVR-10H-T1F-S* |
15 kVA | 68A | 65A | 62A | SVR-15H-T1F-S* |
20 kVA | 90A | 87A | 83A | SVR-20H-T1F-S* |
30 kVA | 136A | 130A | 125A | SVR-30H-T1F-S* |
40 kVA | 181A | 173A | 166A | SVR-40H-T1F-S* |
50 kVA | 227A | 217A | 208A | SVR-50H-T1F-S* |
Note: All SVR-T1F Stabilisers are designed to support the full load at minimum input volts and maximum ambient temperature.
Also available as a Voltage Step-Down Solution (HL Models)
Ideal for applications where the utility supply voltage is different from the load equipment’s requirements (eg Utility Mains Input 230V / Load Requirement 120V)
SELECT | Permissible Input Voltage Window Options (–S*):
Swing Options | Nominal Voltage | Max Model Rating | ||||
110V | 115V | 120V | 127V | |||
S15 | ±15% | 94 to 127V | 98 to 132V | 102 to 138V | 106 to 146V | 30 kVA |
S20 | ±20% | 88 to 132V | 92 to 138V | 96 to 144V | 102 to 152V | 30 kVA |
S25 | ±25% | 83 to 138V | 86 to 144V | 90 to 150V | 95 to 159V | 20 kVA |
S30 | ±30% | 77 to 143V | 81 to 150V | 84 to 156V | 89 to 165V | 15 kVA |
SELECT | Required Power Rating:
Power Rating (kVA) | Max Rating (Amps per Phase) | SVR-L-T1F Model No (S*=Add Swing Option No) | |||
110V | 115V | 120V | 127V | ||
6 kVA | 54.5A | 52.2A | 50.0A | 47.2A | SVR-6L-T1F-S* |
8 kVA | 72A | 69A | 66A | 63A | SVR-8L-T1F-S* |
10 kVA | 90A | 87A | 83A | 78A | SVR-10L-T1F-S* |
15 kVA | 136A | 130A | 125A | 118A | SVR-15L-T1F-S* |
20 kVA | 181A | 173A | 166A | 157A | SVR-20LP-T1F-S* |
30 kVA | 272A | 260A | 250A | 236A | SVR-30L-T1F-S* |
Note:
All SVR Stabilisers are designed to support the full load at minimum input volts and maximum ambient temperature
Also available as a Voltage Step-Up Solution (LH Models)
Ideal for applications where the utility supply voltage is different from the load equipment’s requirements (eg Utility Mains Input 120V / Load Requirement 230V)
General Technical Specification
General: | ||
– Design Topology: | Servo Electronic – Variable Transformer controlled | |
– Phase: | Single Phase, 2 Wire (L+N+GE) | |
– Model Nos: | H Series | SVR-6H-T1F-S* to SVR-50H-T1F-S* ( 5 to 50 kVA) |
L Series | SVR-6L-T1F-S* to SVR-30L-T1F-S* (5 to 30 kVA) | |
– Power Ratings: | 8 Model Ratings- 6 kVA, 8 kVA, 10kVA, 15kVA, 20kVA, 30kVA, 40kVA & 50kVA | |
– Frequency: | 50 / 60Hz (35 to 63Hz) | |
– Power Factor: | The Power Factor has no effect on performance providing the stabilizer is being used within its rated capacity | |
Input: | ||
– Nominal Voltage: | H Series | 220V – 230V – 240V, Single Phase, 2 Wire (L+N+GE) |
L Series | 110V – 120V – 127V, Single Phase, 2 Wire (L+N+GE) | |
– Input Voltage Window Options (S*): | S15 | Nominal ±15% (All Series) |
S20 | Nominal ±20% (All Series) | |
S25 | Nominal ±25% (All Series) | |
S30 | Nominal ±30% (All Series) | |
S35 | Nominal ±35% (H Series Only) | |
S40 | Nominal ±40% (H Series Only) | |
Output: | ||
– Voltage: | H Series | 220V – 230V – 240V (Selectable), Single Phase, 2 Wire (L+N+GE) |
L Series | 110V – 120V – 127V (Selectable), Single Phase, 2 Wire (L+N+GE) | |
– Voltage Accuracy: | S15 to S30 Option Models | ±3% (Default) – adjustable ±1% to ±5% via Front Display Panel |
S35 to S40 Option Models | ±3% (Default) – adjustable ±3% to ±5% via Front Display Panel | |
– Response Time: | Typically a 10% supply variation will be corrected to within 2.5% in 0.6 seconds | |
– Efficiency: | ≥98% | |
Metering, Alerts & Communication: | ||
– Front Display Panel: | Digital Metering: | Input Volts, Output Volts, and Load |
Status Indication: | Overload, Over-Volts, Under-Volts, & Fuse Blown | |
Display Settable Parameters: | Output Voltage, Output Voltage Accuracy, Correction Time, Over-Voltage Level, Under-Voltage Level & Over Current Limit | |
– Interface: | RS-485 – DB9 Pin Style Port | |
Protection Features: | ||
– Surge Protection: | TVSS – Protects loads against high-energy Spikes and Transient Voltages | |
– Lightning Surge Protection: | Class II SPD – protection against extremely high voltage surges and transients caused by lightning strikes on the utility mains supply line | |
– Input Breaker: | Standard on all models – delivers over current input protection | |
– Manual Bypass: | ‘Break Before Make’ bypass facility (with mechanical interlocking) offering the ability to route the supply feed to bypass the stabiliser/conditioner. Useful when performing deep maintenance on the system, or in the highly unlikely event of a system malfunction. | |
– Output Isolation: | Automatic disconnection of the load in the event of a fault condition being detected | |
– Automatic Bypass: | Automatic transfer to Bypass in the event of an overload or unlikely system fault | |
– Overload Ratings: | 10 x max. current rating for 2 seconds 3 x max. current rating for 1 minute 2 x max. current rating for 2 minutes | |
Environmental: | ||
– Operating Temperature Range: | -15°C to +45°C Derate by 2% for each additional °C up to max 60°C | |
– Maximum Altitude: | 1000 meters (derate by 2.5% per additional 500 meters) | |
– Relative Humidity: | Suitable for indoor tropical use – 0 to 95% (non-condensing) | |
Physical: | ||
– Power Connections: | Hardwire Input & Output (with bottom cable entry) | |
– Construction: | IP20 / NEMA 1 Style – BS EN 60529 | |
– Paint Colour: | RAL 1013 (Oyster White – Epoxy Powder Coating) | |
– Dimensions & Weights: | Dependent on model rating and configuration Sizes and weights available on individual request | |
Certification & Conformance: | ||
– EMC Conformance: | BS EN 55022 and relevant parts of BS EN 61000 | |
– CE Certification: | CE Marked – 2014/30/EU (The EMC Directive) and 2014/35/EU (The Low Voltage Directive) | |
– Warranty: | 2 Years / 24 Months from date of supply | |
Optional Add-Ons: | ||
– Outdoor IP54 Enclosure (-IP54) | Stabiliser presented in endurable IP54 (BS / EN 60529) / NEMA 3 free-standing steel cubicles suitable for external use, or more challenging internal environments | |
– Input Isolating Transformer (-PC) | Through the integration of a shielded isolation transformer, provides enhanced spike & electrical noise (Common Mode: 120db @ 100khz & Normal Mode Noise: 60db @ 100khz) suppression and neutral ground bonding. Delivers what is commonly referred to as a ‘CLEAN’ supply | |
– AquaStop (-AS) | PCB protective coating offering protection against damp and moisture ingress | |
– Additional Digital Metering (-ADM) | Additional Digital Metering for Frequency & Power Factor | |
– Output Circuit Breaker (-OCB) | Replacement of the Output Contactor with an Output Circuit Breaker | |
– Alternative Paint Colour (-RAL) | Alternative Paint Colour Finish – customer to specify |
Note:
All SVR Stabilisers are designed to support the full load at minimum input volts and maximum ambient temperature.
Sales & Support
Data Sheet – H Series [220V, 230V, or 240V Models] | |
Data Sheet – L Series [100V, 110V, 115V, 120V or 127V Models] | |
Guide Specification | |
Operator / User Manual |
CE Certification
SVR Series Single Phase Servo Electronic AC Voltage Stabilisers / Conditioners comply with the relevant European Union (EU) health, safety and environmental protection directives and regulations and are duly CE marked.
Ashley-Edison Declaration
Machine (MD) Directive – 2006/42/EC – in force from December 2009 EMC Directive – 2014/30/EU – in force from April 2016 Low Voltage Directive – 2014/35/EU – in force from April 2016 |
Independant 3rd party verification certificate
Machine (MD) Directive – 2006/42/EC – in force from December 2009 |
If you do not find the Voltage Stabiliser or Power Line Conditioner that meets your application’s exact needs, please contact us with your specific detailed requirements.