Single Phase Variable Voltage and Frequency Converters

Display Panel - Single Phase Variable Voltage and Frequency ConvertersSingle Phase Variable Voltage and Frequency Converters in ratings from 2 to over 30 kVA. 

Ashley-Edison's Variable Voltage and Frequency Converters provide an infinitely variable step-less output voltage and frequency that can be adjusted from 0 to 300V and 40 to 499Hz - making them ideal for use in Testing Centres, Research Laboratories and for testing on Production Lines.

Solid State in basic design, the only moving parts are the fans used to cool the system.

Models available for nominal input Voltages of 220 to 240V (H Series - International) and 110 to 127V (L Series - US)

 

Introduction

FCL-H Series - 2 to 30 kVA
Single Phase Variable Voltage and Frequency Converters

Nominal Input Voltage
220 to 240V Single Phase, 50/60Hz

 

Single Phase AC Variable Voltage and Frequency Converter

  • Ability to replicate all the numerous Nominal Utility Single Phase Voltages (eg. 100 to 277V) and Frequencies (40 to 499.99Hz) deployed throughout the World

  • Suitable for use with Resistive, Capacitive, Inductive and Non-Linear Loads.

  • Galvanically isolated with Pure and Stable Sine Wave Output delivering minimal Harmonic Distortion (EMC/EMC).

  • Selectable High or Low Output Voltage Ranges

  • High Overload Capability

  • PWM/IGBT design ensures High Efficiency and Low Noise, whilst delivering Maximum Reliability.

  • Uncomplicated and Simple to use Set-up and Operation

  • East to read LED Digital Metering - displaying Output Frequency, Voltage, Current and Loading - eliminating the need for external monitoring

 

Downloads

eDataSheet FlipBook
PDF DataSheet pdf

 

 

 

 

 

Pricing

To obtain a personal price, or to discuss further how we might be able to help your organisation, please feel free

 to either e-mail us
 or call us on +44 (0)870 240 6162

Get ADOBE READER  Get Adobe Flash Player

Input and Output Voltage and Frequency Options

INPUT   OUTPUT
 Nominal AC Single Phase Input Voltage & Frequency    Input Voltage Window - S10 Available AC Output Voltage Selectable High or Low Current Output Voltage Ranges Output Voltage Accuracy ±% of Output Progammeable Output Frequency Output Frequency Accuracy ±% of Output
220V 198 to 242V 0V to 300V

High Level

0 to 300V

±1%

40 to 499.9 Hz

±0.01%

50 or 60 Hz (220V ±10%)

Low Level

0 to 150V

230V 207 to 253V

0V to 300V

High Level

0 to 300V

±1%

40 to 499.9 Hz

±0.01%

 50 or 60 Hz (230V ±10%)

Low Level

0 to 150V

240V 215 to 264V 0V to 300V High Level 0 to 300V ±1% 40 to 499.9 Hz ±0.01%
50 or 60 Hz (240V ±10%) Low Level 0 to 150V

   Note: Other voltage configurations available upon enquiry / order.

Model Selection Table

Ashley-Edison Model No:
Power Rating   Max. Current for Selectable High or Low Current Output Voltage Ranges Physical Size & Weights
High Low
kVA (kW) Amps W x H x D mm Kg
FCL-2H-S10 2 kVA (1.6 kW) 8.3

16.6

350 x 535 x 700

40

FCL-3H-S10 3 kVA (2.4 kW)

12.5

25.0

350 x 535 x 700

50

FCL-5H-S10 5 kVA (4 kW)

20.8

61.6

350 x 535 x 700

60

FCL-10H-S10 10 kVA (8 kW)

41.7

83.4

420 x 640 x 920

90

FCL-15H-S10 15 kVA (12 kW)

62.5

125.0

420 x 640 x 920

110

FCL-20H-S10 20 kVA (16 kW)

83.3

166.6

420 x 640 x 920

140

FCL-30H-S10 30 kVA (24 kW) 125.0 250.0 550 x 770 x 1110 180

   Note: Larger rated models available upon enquiry / order.

Technical Specification

   General:
  Phase Single Phase, 2 Wire, (1P+Neutral+G/E)
  Ashley-Edison Models FCL-2H-S10 to FCL-30H-S10
  Power Ratings 7 Models - Ratings
2kVA (1.6kW), 3kVA (2.4kW), 5kVA (4kW), 10kVA (8kW),
15kVA (12kW), 20kVA (16kW) & 30kVA (24kW)
- Larger ratings to special order
  Design Topology  Static - IGBT/Pulse Width Modulated (PWM)
   Input:
  Voltage

 

220V - 230V - 240V ±10%
  Frequency   47 to 63Hz ±5%  (400Hz Option)
   Output:
  Selectable High or Low Current
Output Voltage Ranges
High Voltage - 0 to 300V
Low Voltage - 0 to 150V
  Voltage Regulation

±1%

  Frequency 40 to 499.9Hz (Programmable Key Lock Setting)
  Frequency Stability  ±0.01%
  Power Factor  0.8 Power Factor
  Digital Metering  Frequency (Hz)  4 Digit LED Digital Display - Resolution 0.1Hz/Step
     Voltage (Volts)  4 Digit LED Digital Display - Resolution 0.1 Volt
     Current (Amps)  4 Digit LED Digital Display - Resolution 0.1 Amp
     Loading (Watts)  4 Digit LED Digital Display - Resolution 0.1 kWatt
   Protection Features:
  As Standard   Electronic Circuit/Circuit Breaker, Overload Warning, Over Temperature,
Short Circuit and Auto-Power Off
   Environmental:
  Operating Temperature Range Temperature range –15 to 45 °C 
Derate by 2% for each additional °C Up to max 60 °C
  Maximum Altitude Maximum altitude 4000m
Derate by 2.5% for each additional 500m
  Relative Humidity Suitable for indoor tropical use 90% RH (non-condensing).
  Efficiency  ≥94%
  THD - Harmonic Distortion  Pure Sinewave ≤2%
  Audible Noise  
   Physical:
  Construction Enclosures to IP20 (NEMA 1 Style) - BS EN 60529
  Colour RAL 7032 (Pebble Grey - Epoxy Powder Coating)
  Dimensions & Weights See Model Selection Table (above)
   Certification & Conformance:
  EMC Conformance Complies with BS EN 55022 and the relevant
parts of the BS EN 61000 series of standards
  CE Certification  CE Marked - being fully compliant with European Union Directives
2014/30/EU (The EMC Directive) and 2014/35/EU (The Low Voltage Directive)
   Warranty:
  Standard Warranty 1 Year / 12 Months from date of supply
  Extended Warranty Option - Extendable Warranty up to 60 Months / 5 Years

     Copyright © Ashley-Edison (UK) reserves the right to change any or all of the specifications indicated or implied without prior notice. E&OE

Introduction

FCL-L Series - 2 to 30 kVA
Single Phase Variable Voltage and Frequency Converters

Nominal Input Voltage
110 to 127V Single Phase, 50/60Hz

 

Single Phase AC Variable Voltage and Frequency Converter

  • Ability to replicate all the numerous Nominal Utility Single Phase Voltages (eg. 100 to 277V) and Frequencies (40 to 499.99Hz) deployed throughout the World

  • Suitable for use with Resistive, Capacitive, Inductive and Non-Linear Loads.

  • Galvanically isolated with Pure and Stable Sine Wave Output delivering minimal Harmonic Distortion (EMC/EMC).

  • Selectable High or Low Output Voltage Ranges

  • High Overload Capability

  • PWM/IGBT design ensures High Efficiency and Low Noise, whilst delivering Maximum Reliability.

  • Uncomplicated and Simple to use Set-up and Operation

  • East to read LED Digital Metering - displaying Output Frequency, Voltage, Current and Loading - eliminating the need for external monitoring

 

Downloads

eDataSheet FlipBook
PDF DataSheet pdf

 

 

 

 

 

Pricing

To obtain a personal price, or to discuss further how we might be able to help your organisation, please feel free

 to either e-mail us
 or call us on +44 (0)870 240 6162

Get ADOBE READER  Get Adobe Flash Player

Input and Output Voltage and Frequency Options

INPUT   OUTPUT
 Nominal AC Single Phase Input Voltage & Frequency    Input Voltage Window - S10 Available AC Output Voltage Selectable High or Low Current Output Voltage Ranges Output Voltage Accuracy ±% of Output Progammeable Output Frequency Output Frequency Accuracy ±% of Output
110V 99 to 121V 0V to 300V

High Level

0 to 300V

±1%

40 to 499.9 Hz

±0.01%

50 or 60 Hz (110V ±10%)

Low Level

0 to 150V

115V 104 to 126V

0V to 300V

High Level

0 to 300V

±1%

40 to 499.9 Hz

±0.01%

 50 or 60 Hz (115V ±10%)

Low Level

0 to 150V

120V 108 to 132V 0V to 300V High Level 0 to 300V ±1% 40 to 499.9 Hz ±0.01%
50 or 60 Hz (120V ±10%) Low Level 0 to 150V
127V 115 to 139V 0V to 300V High Level 0 to 300V ±1% 40 to 499.9 Hz ±0.01%
50 or 60 Hz (127V ±10%) Low Level 0 to 150V

   Note: Other voltage configurations available upon enquiry / order.

Model Selection Table

Ashley-Edison Model No:
Power Rating   Max. Current for Selectable High or Low Current Output Voltage Ranges Physical Size & Weights
High Low
kVA (kW) Amps W x H x D mm Kg
FCL-2L-S10 2 kVA (1.6 kW) 8.3

16.6

Available on individual request

FCL-3L-S10 3 kVA (2.4 kW)

12.5

25.0

FCL-5L-S10 5 kVA (4 kW)

20.8

61.6

FCL-10L-S10 10 kVA (8 kW)

41.7

83.4

FCL-15L-S10 15 kVA (12 kW)

62.5

125.0

FCL-20L-S10 20 kVA (16 kW)

83.3

166.6

FCL-30H-S10 30 kVA (24 kW) 125.0 250.0

   Note: Larger rated models available upon enquiry / order.

Technical Specification

   General:
  Phase Single Phase, 2 Wire, (1P+Neutral+G/E)
  Ashley-Edison Models FCL-2L-S10 to FCL-30H-S10
  Power Ratings 7 Models - Ratings
2kVA (1.6kW), 3kVA (2.4kW), 5kVA (4kW), 10kVA (8kW),
15kVA (12kW), 20kVA (16kW) & 30kVA (24kW)
- Larger ratings to special order
  Design Topology  Static - IGBT/Pulse Width Modulated (PWM)
   Input:
  Voltage

 

110V - 115V - 120V - 127V ±10%
  Frequency   47 to 63Hz ±5%  (400Hz Option)
   Output:
  Selectable High or Low Current
Output Voltage Ranges
High Voltage - 0 to 300V
Low Voltage - 0 to 150V
  Voltage Regulation

±1%

  Frequency 40 to 499.9Hz (Programmable Key Lock Setting)
  Frequency Stability  ±0.01%
  Power Factor  0.8 Power Factor
  Digital Metering  Frequency (Hz)  4 Digit LED Digital Display - Resolution 0.1Hz/Step
     Voltage (Volts)  4 Digit LED Digital Display - Resolution 0.1 Volt
     Current (Amps)  4 Digit LED Digital Display - Resolution 0.1 Amp
     Loading (Watts)  4 Digit LED Digital Display - Resolution 0.1 kWatt
   Protection Features:
  As Standard   Electronic Circuit/Circuit Breaker, Overload Warning, Over Temperature,
Short Circuit and Auto-Power Off
   Environmental:
  Operating Temperature Range Temperature range –15 to 45 °C 
Derate by 2% for each additional °C Up to max 60 °C
  Maximum Altitude Maximum altitude 4000m
Derate by 2.5% for each additional 500m
  Relative Humidity Suitable for indoor tropical use 90% RH (non-condensing).
  Efficiency  ≥94%
  THD - Harmonic Distortion  Pure Sinewave ≤2%
  Audible Noise  
   Physical:
  Construction Enclosures to IP20 (NEMA 1 Style) - BS EN 60529
  Colour RAL 7032 (Pebble Grey - Epoxy Powder Coating)
  Dimensions & Weights See Model Selection Table (above)
   Certification & Conformance:
  EMC Conformance Complies with BS EN 55022 and the relevant
parts of the BS EN 61000 series of standards
  CE Certification  CE Marked - being fully compliant with European Union Directives
2014/30/EU (The EMC Directive) and 2014/35/EU (The Low Voltage Directive)
   Warranty:
  Standard Warranty 1 Year / 12 Months from date of supply
  Extended Warranty Option - Extendable Warranty up to 60 Months / 5 Years

     Copyright © Ashley-Edison (UK) reserves the right to change any or all of the specifications indicated or implied without prior notice. E&OE

If you do not find the Variable Voltage and Frequency Converter that meets your application's exact needs, please contact us with your specific detailed requirements.




This website uses 'cookies' to give you the best, most relevant experience. Using this website means you’re OK with this. You can change which cookies are set at any time - and find out more about them - by following this link, or by clicking the cookie link at the bottom of any page.
This message will close within 20 seconds.

Accept all cookies