Outdoor Single Phase Voltage Stabilizers

SES Series - IP54 / NEMA 3 - 3 to 100 kVA

With a fast speed of response and unparalleled inbuilt protection features, OSES Single Phase IP54 / NEMA 3 style Voltage Stabilizers deliver cost efficient voltage stabilisation, voltage surge and spike protection without compromising on technical performance or quality.

Features

OSES – Outdoor IP54 Single Phase Voltage Stabilizers

 -

Step-Less Voltage Control

 -

Wide range of permissible input voltage windows (±15% to ±40%)

 -

±1% Output Voltage Accuracy

 -

IP54 / NEMA 3 Style Enclosure

 -

Inbuilt TVSS - Transient Voltage Surge & Spike Suppression

 -

High Overload Capability

 -

Start Up Load Protection

 -

Input Breaker fitted as Standard

 -

Lightning Surge Protection

 -

Extremely Low Maintenance

 -

2 Years Warranty

 To learn more please check-out the series listings below

 

    Watch the Video

OSES Single Phase Video
 > IP54 / NEMA 3 ?    
 

   The Ranges

   Series

  Voltages

    H

  International Voltages (220 - 240V)

    L

  US Voltages (100 - 127V)

    HL

  Step-Down Voltage Converter (Int to US)

    LH

  Step-Up Voltage Converter (US to Int)

For full Series details see below.   

Introduction

OSES-H-S Series - 3 to 100 kVA
Outdoor IP54 / NEMA 3 Style Single Phase Servo Electronic AC Voltage Stabilisers

1P 2W Solution

Input / Output:  220V, 230V & 240V AC -  50/60Hz


Our most popular and feature rich Single Phase offering configured for International / European voltages. Ideal for over 95% of all general commercial and industrial applications.

Standard Permissible Input Voltage Window Options

SWING-OSES-H-S

> View Input Voltage Swings

In situations where there is a reasonably good mains supply, a Stabiliser offering an input variation swing of ±15% (S15 Models) will usually be more than acceptable, but in more remote locations, or countries where the national supply infrastructure is less developed, variations of ±20% or greater may be needed to be accommodated by the Stabiliser.

TIP - The wider the permissible input voltage window you wish the Stabiliser to accomodate and the more accurate the voltage you require on the output, the more expensive the Stabiliser. So, when selecting the most appropriate and cost efficient model for your application, it pays to know the state of the utility mains supply on site and the designed input voltage tolerances of the load equipment you wish to protect.

 

Downloads

General Series Catalogue: pdf
Guide Specification: doc
Servo Electronic Overview Brochure: pdf



 

 

Pricing

To obtain a personal price, or to discuss further how we might be able to help your organisation, please feel free

 to either e-mail us
 or call us on +44 (0)870 240 6162
 

Get ADOBE READER  Get Adobe Flash Player

Model Ratings (kVA/Amps)

Power
Rating
kVA

Max. Amps

 


















AE Model No: 

Enclosure
Style / Type

Dimensions
W x H x D (mm)

Weight
(Kgs)

@220V @230V @240V
3 kVA 13.6 13.0 12.5 OSES-3H-S* Dimensions, Weights and precise Standard & 
Optional Features as per the 
relevant S* model data sheet
or upon request.
4 kVA 18 17 16 OSES-4H-S*
5 kVA 23 22 21 OSES-5H-S*
8 kVA 36 35 33 OSES-8H-S*
10 kVA 46 44 42 OSES-10H-S*
15 kVA 66 65 63 OSES-15H-S*
20 kVA 91 87 83 OSES-20H-S*
30 kVA 136 130 125 OSES-30H-S*
40 kVA 182 174 167 OSES-40H-S*
50 kVA 227 217 208 OSES-50H-S*
60 kVA 273 261 250 OSES-60H-S*
75 kVA 341 326 313 OSES-75H-S*
100 kVA 455 435 417 OSES-100H-S*
 
   S* = Selected permissible input voltage window - S15 (±15%), S20 (±20%), S25 (±25%), S30 (±30%), S35 (±35%) or S40 (±40%)
 
   Note:    Other voltage configurations available upon enquiry / order. 
  Optional Accessories added may affect dimensions and weights - subject to confirmation.
  For packed, sizes and weights please refer to the FAQ Section of this site.

General Technical Specification

 Technology:

Servo Electronic - Variable Transformer controlled, series regulation transformer (buck-boast transformer with secondary wired in series with the load).

Permissible Input Voltage Window Options >

220V, 230V or 240V (Customer to specify) – 2 Wire (1 Phase + Neutral + G/E)

With Output Voltage Accuracy

±1%

±3%

±5%

Ratings

*S15 Models– Input Window

± 15%

-17% /+18%

-19% /+21%

3 to 100 kVA

*S20 Models– Input Window

± 20%

-22% / +23%

-24% / +26%

3 to 75 kVA

*S25 Models– Input Window

± 25%

-27% / +28%

-29% / +31%

3 to 60 kVA

*S30 Models– Input Window

± 30%

-32% / +33%

-34% / +36%

3 to 50 kVA

*S35 Models– Input Window

± 35%

-37% / +38%

-39% / +41%

3 to 40 kVA

*S40 Models– Input Window

± 40%

-42% / +43%

-44% / +46%

3 to 30 kVA

Output Voltage:

220V, 230V or 240V AC (Customer to specify) – 2 Wire (1 Phase + Neutral + G/E)

Output Voltage Accuracy:

± 1%, ± 3% or ± 5% - auto selection based on input voltage swing

Frequency:

47 to 65 Hz

Response Time:

< 1.5 ms

Correction Time:

A 10% supply variation will be corrected to within 2.5% in 0.6 seconds.

Efficiency:

98%

Power Factor:

Any Lagging to 0.95 leading

Surge Ratings:

10 x max current rating for 2 seconds

 

3 x max current rating for 1 minute

 

2 x max current rating for 5 minutes

Surge Suppression:

TVSS - Protects loads against high energy Spikes and Transient Voltages

  Surge Arrestors:

40kA at 275V AC Class III

(IEC 61643-1: 1998-2, EN 61643-11: 2001)

Total Harmonic Distortion:

 < 1%

Soft-Switch-On:

Ensures the output voltage is set to a minimum upon Switch-On before commencing stabilization - protects load equipment from damaging start-up voltage surges.

Environment:

Temperature Range -15°to 45° C

 

Derate by 2% for each additional °C up to max 60°C

 

Suitable for indoor tropical use 95% RH (non-condensing)

 

Maximum altitude 1000m. Derate by 2.5% for each additional 500m.

Paint Colour:

RAL 7032 (Grey - Powder Coat)

Construction:

Enclosures to IP54 (NEMA 3 Style), BS EN 60529

Conformance:

Complies with BS EN 55022 and the relevant parts of BS EN 61000 series of standards

 CE Conformity:

CE Marked - being fully compliant with European Union Directives 2004/108/EC (replaced EMC Directive 89/336/EEC from July 2009) and 2006/95/EC (The Low Voltage Directive in force from January 2007)

Warranty:

Two (2) Years / Twenty-Four (24) Months from date of supply.

Extendable, by purchasing an Extended Warranty, to Five (5) Years / Sixty (60 Months).

 Standard Features:

Input Circuit Breaker

Input Output Terminals

Lightning Surge Arrestor

Bypass Control Switch

Voltmeter - Internal

Optional Accessories:

Over / Low Voltage Protection

 

Ammeter

 

Output Breaker

 

No Volt Contacts

 

Inbuilt Manual Maintenance Bypass Switch

 

Thermostatically Controlled Heater

 

Digital Power Metering - showing V, A, W, VA, AER, PF & KWH (with RS-482 Interface)

 

AquaStop Protective Coating - protection against damp and moisture ingress

IP 55 Ingress Protection

 

 

Please Note– These Stabilisers are not designed to support / protect voltage “back feed” applications, where energy is required to be also fed back into the utility supply.

Introduction

 US Voltages

OSES-L-S Series - 3 to 40 kVA
Outdoor IP54 / NEMA 3 Style Single Phase Servo Electronic AC Voltage Stabilizers

1P 2W Solution

Input / Output:  100V, 110V, 115V, 120V & 127V AC  -  50/60Hz


Our most popular and feature rich Single Phase offering configured for US voltages. Ideal for over 95% of all general commercial and industrial applications. 

Standard Permissible Input Voltage Window Options

SWING-OSES-L-S

> View Input Voltage Swings

In situations where there is a reasonably good mains supply, a Stabilizer offering an input variation swing of ±15% (S15 Models) will usually be more than acceptable, but in more remote locations, or countries where the national supply infrastructure is less developed, variations of ±20% or greater may be needed to be accommodated by the Stabilizer.

TIP - The wider the permissible input voltage window you wish the Stabilizer to accomodate and the more accurate the voltage you require on the output, the more expensive the Stabilizer. So, when selecting the most appropriate and cost efficient model for your application, it pays to know the state of the utility mains supply on site and the designed input voltage tolerances of the load equipment you wish to protect.

 

Downloads

General Series Catalog: pdf
Guide Specification: doc
Servo Electronic Overview Brochure: pdf

 

 

 

Pricing

To obtain a personal price, or to discuss further how we might be able to help your organisation, please feel free

 to either e-mail us
 or call us on +44 (0)870 240 6162
 

Get ADOBE READER  Get Adobe Flash Player

Model Ratings (kVA/Amps)

Power
Rating
kVA

Max. Amps

 


















AE Model No: 

Enclosure
Style / Type

Dimensions
W x H x D (mm)

Weight
(Kgs)

@100V @110V @115V @120V @127V
3 kVA 30 27 26  25 23 OSES-3L-S*

Dimensions, Weights and precise Standard &
Optional Features as per the 
relevant S* model data sheet
or upon request.

4 kVA 40 36 34 33 31 OSES-4L-S*
5 kVA 50 45 43 41 39 OSES-5L-S*
8 kVA 80 72 69 66 63 OSES-8L-S*
10 kVA 100 90 87 83 78 OSES-10L-S*
15 kVA 150 136 130 125 118 OSES-15L-S*
20 kVA 200 181 173 166 157 OSES-20L-S*
30 kVA 300 272 260 250 236 OSES-30L-S*
40 kVA 400 363 347 333 315 OSES-40L-S*
 
   S* = Selected permissible input voltage window - S15 (±15%), S20 (±20%), S25 (±25%), S30 (±30%), S35 (±35%) or S40 (±40%)
 
   Note:    Other voltage configurations available upon enquiry / order. 
  Optional Accessories added may affect dimensions and weights - subject to confirmation.
  For packed, sizes and weights please refer to the FAQ Section of this site.

General Technical Specification

 Technology:

Servo Electronic - Variable Transformer controlled, series regulation transformer (buck-boast transformer with secondary wired in series with the load).

Permissible Input Voltage Window Options >

100V, 110V,115V, 120V or 127V  (Customer to specify) – 2 Wire (1 Phase + Neutral + G/E)

With Output Voltage Accuracy

±1%

±3%

±5%

Ratings

*S15 Models– Input Window

± 15%

-17% /+18%

-19% /+21%

3 to 40 kVA

*S20 Models– Input Window

± 20%

-22% / +23%

-24% / +26%

3 to 30 kVA

*S25 Models– Input Window

± 25%

-27% / +28%

-29% / +31%

3 to 30 kVA

*S30 Models– Input Window

± 30%

-32% / +33%

-34% / +36%

3 to 20 kVA

*S35 Models– Input Window

± 35%

-37% / +38%

-39% / +41%

3 to 15 kVA

*S40 Models– Input Window

± 40%

-42% / +43%

-44% / +46%

3 to 15 kVA

  Output Voltage:

100V, 110V, 115V, 120V or 127V  (Customer to specify) – 2 Wire (1 Phase + Neutral + G/E)

  Output Voltage Accuracy:

± 1%, ± 3% or ± 5% - auto selection based on input voltage swing

  Frequency:

47 to 65 Hz

  Response Time:

< 1.5 ms

  Correction Time:

A 10% supply variation will be corrected to within 2.5% in 0.6 seconds.

  Efficiency:

98%

  Power Factor:

Any Lagging to 0.95 leading

  Surge Ratings:

10 x max current rating for 2 seconds

 

3 x max current rating for 1 minute

 

2 x max current rating for 5 minutes

  Surge Suppression:

TVSS - Protects loads against high energy Spikes and Transient Voltages

  Total Harmonic Distortion:

 < 1%

  Soft-Switch-On:

Ensures the output voltage is set to a minimum upon Switch-On before commencing stabilization - protects load equipment from damaging start-up voltage surges.

  Environment:

Temperature Range -15°to 45° C

 

Derate by 2% for each additional °C up to max 60°C

 

Suitable for indoor tropical use 95% RH (non-condensing)

 

Maximum altitude 1000m. Derate by 2.5% for each additional 500m.

  Paint Colour:

RAL 7032 (Grey - Powder Coat)

  Construction:

Enclosures to IP54 (NEMA 3 Style), BS EN 60529

  Conformance:

Complies with BS EN 55022 and the relevant parts of BS EN 61000 series of standards

  CE Conformity:

CE Marked - being fully compliant with European Union Directives 2004/108/EC (replaced EMC Directive 89/336/EEC from July 2009) and 2006/95/EC (The Low Voltage Directive in force from January 2007)

  Warranty:

Two (2) Years / Twenty-Four (24) Months from date of supply.

Extendable, by purchasing an Extended Warranty, to Five (5) Years / Sixty (60 Months).

   Standard Features:

Input Circuit Breaker

Input Output Terminals

Bypass Control Switch

Voltmeter - Internal

  Optional Accessories:

Over / Low Voltage Protection

 

Ammeter

 

Output Breaker

 

No Volt Contacts

 

Inbuilt Manual Maintenance Bypass Switch

 

Lightning Surge Arrestors

 

Digital Power Metering - showing V, A, W, VA, AER, PF & KWH (with RS-482 Interface)

 

AquaStop Protective Coating - protection against damp and moisture ingress

IP 55 Ingress Protection

 

 

Please Note– These Stabilisers are not designed to support / protect voltage “back feed” applications, where energy is required to be also fed back into the utility supply.

Introduction

OSES-HL-S Series - 3 to 30 kVA
Outdoor IP54 / NEMA 3 Style Single Phase Servo Electronic Step-Down AC Voltage Stabilisers / Voltage Converters

3P 4W Solution

Input:      220V, 230V or 240V AC -  50/60Hz

Output:   100V, 110V, 115V, 120V or 127V AC -  50/60Hz

 

Step-Down Voltage Converters which also deliver protection against the vagaries of voltage fluctuations on the input utility supply. Ideal for applications where the utility supply voltage is different from the load equipment’s requirement eg. US designed equipment used in Europe.

Standard Permissible Input Voltage Window Options

SWING-OSES-HL-S

View Input Voltage Swings

In situations where there is a reasonably good mains supply, a Stabiliser offering an input variation swing of ±15% (S15 Models) will usually be more than acceptable, but in more remote locations, or countries where the national supply infrastructure is less developed, variations of ±20% or greater may be needed to be accommodated by the Stabiliser.

TIP - The wider the permissible input voltage window you wish the Stabiliser to accomodate and the more accurate the voltage you require on the output, the more expensive the Stabiliser. So, when selecting the most appropriate and cost efficient model for your application, it pays to know the state of the utility mains supply on site and the designed input voltage tolerances of the load equipment you wish to protect.

 

Downloads

General Series Catalogue: pdf 
Guide Specification: doc
Servo Electronic Overview Brochure: pdf

 

 

 

Pricing

To obtain a personal price, or to discuss further how we might be able to help your organisation, please feel free

 to either e-mail us
 or call us on +44 (0)870 240 6162
 

Get ADOBE READER  Get Adobe Flash Player

Model Ratings (kVA/Amps)

Power
Rating
kVA

Max. Amps

 


















AE Model No: 

Enclosure
Style / Type

Dimensions
W x H x D (mm)

Weight
(Kgs)

@100V @110V @115V @120V @127V
3 kVA 30 27 26  25 23 OSES-3HL-S*

Dimensions, Weights and precise Standard and Optional Features as per the relevant S* model data sheet or upon request.

 

NB:  FREQUENCY CONVERSION - Where Frequency Conversion  is also required a separate standalone Frequency Converter will be required

                        
4 kVA 40 36 34 33 31 OSES-4HL-S*
5 kVA 50 45 43 41 39 OSES-5HL-S*
8 kVA 80 72 69 66 63 OSES-8HL-S*
10 kVA 100 90 87 83 78 OSES-10HL-S*
15 kVA 150 136 130 125 118 OSES-15HL-S*
20 kVA 200 181 173 166 157 OSES-20HL-S*
30 kVA 300 272 260 250 236 OSES-30HL-S*
 
   S* = Selected permissible input voltage window - S15 (±15%), S20 (±20%), S25 (±25%), S30 (±30%), S35 (±35%) or S40 (±40%)
 
   Note:    Other voltage configurations available upon enquiry / order. 
  Optional Accessories added may affect dimensions and weights - subject to confirmation.
  For packed, sizes and weights please refer to the FAQ Section of this site.

General Technical Specification

 Technology:

Servo Electronic - Variable Transformer controlled, series regulation transformer (buck-boast transformer with secondary wired in series with the load).

Permissible Input Voltage Window Options >

220V, 230V or 240V (Customer to specify) – 2 Wire (1 Phase + Neutral + G/E)

With Output Voltage Accuracy

±1%

±3%

±5%

Ratings

*S15 Models– Input Window

± 15%

-17% /+18%

-19% /+21%

3 to 30 kVA

*S20 Models– Input Window

± 20%

-22% / +23%

-24% / +26%

3 to 30 kVA

*S25 Models– Input Window

± 25%

-27% / +28%

-29% / +31%

3 to 30 kVA

*S30 Models– Input Window

± 30%

-32% / +33%

-34% / +36%

3 to 30 kVA

*S35 Models– Input Window

± 35%

-37% / +38%

-39% / +41%

3 to 15 kVA

*S40 Models– Input Window

± 40%

-42% / +43%

-44% / +46%

3 to 15 kVA

  Output Voltage:

100V, 110V, 115V, 120V or 127V  (Customer to specify) – 2 Wire (1 Phase + Neutral + G/E)

  Output Voltage Accuracy:

± 1%, ± 3% or ± 5% - auto selection based on input voltage swing

  Frequency:

47 to 65 Hz

  Response Time:

< 1.5 ms

  Correction Time:

A 10% supply variation will be corrected to within 2.5% in 0.6 seconds.

  Efficiency:

98%

  Power Factor:

Any Lagging to 0.95 leading

  Surge Ratings:

10 x max current rating for 2 seconds

 

3 x max current rating for 1 minute

 

2 x max current rating for 5 minutes

  Surge Suppression:

TVSS - Protects loads against high energy Spikes and Transient Voltages

  Surge Arrestors:

40kA at 275V AC Class III

(IEC 61643-1: 1998-2, EN 61643-11: 2001)

  Total Harmonic Distortion:

 < 1%

  Soft-Switch-On:

Ensures the output voltage is set to a minimum upon Switch-On before commencing stabilization - protects load equipment from damaging start-up voltage surges.

  Environment:

Temperature Range -15°to 45° C

 

Derate by 2% for each additional °C up to max 60°C

 

Suitable for indoor tropical use 95% RH (non-condensing)

 

Maximum altitude 1000m. Derate by 2.5% for each additional 500m.

  Paint Colour:

RAL 7032 (Grey - Powder Coat)

  Construction:

Enclosures to IP54 (NEMA 3 Style), BS EN 60529

  Conformance:

Complies with BS EN 55022 and the relevant parts of BS EN 61000 series of standards

  CE Conformity:

CE Marked - being fully compliant with European Union Directives 2004/108/EC (replaced EMC Directive 89/336/EEC from July 2009) and 2006/95/EC (The Low Voltage Directive in force from January 2007)

  Warranty:

Two (2) Years / Twenty-Four (24) Months from date of supply.

Extendable, by purchasing an Extended Warranty, to Five (5) Years / Sixty (60 Months).

   Standard Features:

Input Circuit Breaker

Input Output Terminals

Lightning Surge Arrestor

Bypass Control Switch

Voltmeter - Internal

  Optional Accessories:

Over / Low Voltage Protection

 

Ammeter

 

Output Breaker

 

No Volt Contacts

 

Inbuilt Manual Maintenance Bypass Switch

 

Thermostatically Controlled Heater

 

Digital Power Metering - showing V, A, W, VA, AER, PF & KWH (with RS-482 Interface)

 

AquaStop Protective Coating - protection against damp and moisture ingress

IP 55 Ingress Protection

 

 

Please Note– These Stabilisers are not designed to support / protect voltage “back feed” applications, where energy is required to be also fed back into the utility supply.

Introduction

US Voltages

OSES-LH-S Series - 3 to 20 kVA
Outdoor IP54 / NEMA 3 Style Single Phase Servo Electronic Step-Up AC Voltage Stabilizers / Voltage Converters

 3P 4W Solution

Input:     100V, 110V, 115V, 120V or 127V AC -  50/60Hz

Output:  220V, 230V or 240V AC -  50/60Hz

 

Step-Up Voltage Converters which also deliver protection against the vagaries of voltage fluctuations on the input utility supply. Ideal for applications where the utility supply voltage is different from the load equipment’s requirement.

Standard Permissible Input Voltage Window Options

SWING-OSES-LH-3P-S

> View Input Voltage Swings

In situations where there is a reasonably good mains supply, a Stabilizer offering an input variation swing of ±15% (S15 Models) will usually be more than acceptable, but in more remote locations, or countries where the national supply infrastructure is less developed, variations of ±20% or greater may be needed to be accommodated by the Stabilizer.

TIP - The wider the permissible input voltage window you wish the Stabilizer to accomodate and the more accurate the voltage you require on the output, the more expensive the Stabilizer. So, when selecting the most appropriate and cost efficient model for your application, it pays to know the state of the utility mains supply on site and the designed input voltage tolerances of the load equipment you wish to protect.

 

Downloads

General Series Catalog: pdf
Guide Specification: doc
Servo Electronic Overview Brochure: pdf

 

 

 

Pricing

To obtain a personal price, or to discuss further how we might be able to help your organisation, please feel free

 to either e-mail us
 or call us on +44 (0)870 240 6162
 

Get ADOBE READER  Get Adobe Flash Player

Model Ratings (kVA/Amps)

Power
Rating
kVA

Max. Amps

 


















AE Model No: 

Enclosure
Style / Type

Dimensions
W x H x D (mm)

Weight
(Kgs)

@220V @230V @240V
3 kVA 13.6 13.0 12.5 OSES-3LH-S*  

Dimensions, Weights and precise Standard and Optional Features as per the relevant S* model data sheet or upon request.

 

NB: FREQUENCY CONVERSION - Where Frequency Conversion is also required a separate standalone Frequency Converter will be required.

4 kVA 18 17 16 OSES-4LH-S*
5 kVA 23 22 21 OSES-5LH-S*
8 kVA 36 35 33 OSES-8LH-S*
10 kVA 46 44 42 OSES-10LH-S*
15 kVA 66 65 63 OSES-15LH-S*
20 kVA 91 87 83 OSES-20LH-S*
 
   S* = Selected permissible input voltage window - S15 (±15%), S20 (±20%), S25 (±25%), S30 (±30%), S35 (±35%) or S40 (±40%)
 
   Note:    Other voltage configurations available upon enquiry / order. 
  Optional Accessories added may affect dimensions and weights - subject to confirmation.
  For packed, sizes and weights please refer to the FAQ Section of this site.

General Technical Specification

 Technology:

Servo Electronic - Variable Transformer controlled, series regulation transformer (buck-boast transformer with secondary wired in series with the load).

Permissible Input Voltage Window Options >

100V, 110V, 115V, 120V or 127V  (Customer to specify) – 2 Wire (1 Phase + Neutral + G/E)

With Output Voltage Accuracy

±1%

±3%

±5%

Ratings

*S15 Models– Input Window

± 15%

-17% /+18%

-19% /+21%

3 to 20 kVA

*S20 Models– Input Window

± 20%

-22% / +23%

-24% / +26%

3 to 20 kVA

*S25 Models– Input Window

± 25%

-27% / +28%

-29% / +31%

3 to 20 kVA

*S30 Models– Input Window

± 30%

-32% / +33%

-34% / +36%

3 to 15 kVA

*S35 Models– Input Window

± 35%

-37% / +38%

-39% / +41%

3 to 10 kVA

*S40 Models– Input Window

± 40%

-42% / +43%

-44% / +46%

3 to 10 kVA

  Output Voltage:

220V, 230V or 240V (Customer to specify) – 2 Wire (1 Phase + Neutral + G/E)

  Output Voltage Accuracy:

± 1%, ± 3% or ± 5% - auto selection based on input voltage swing

  Frequency:

47 to 65 Hz

  Response Time:

< 1.5 ms

  Correction Time:

A 10% supply variation will be corrected to within 2.5% in 0.6 seconds.

  Efficiency:

98%

  Power Factor:

Any Lagging to 0.95 leading

  Surge Ratings:

10 x max current rating for 2 seconds

 

3 x max current rating for 1 minute

 

2 x max current rating for 5 minutes

  Surge Suppression:

TVSS - Protects loads against high energy Spikes and Transient Voltages

  Total Harmonic Distortion:

 < 1%

  Soft-Switch-On:

Ensures the output voltage is set to a minimum upon Switch-On before commencing stabilization - protects load equipment from damaging start-up voltage surges.

  Environment:

Temperature Range -15°to 45° C

 

Derate by 2% for each additional °C up to max 60°C

 

Suitable for indoor tropical use 95% RH (non-condensing)

 

Maximum altitude 1000m. Derate by 2.5% for each additional 500m.

  Paint Colour:

RAL 7032 (Grey - Powder Coat)

  Construction:

Enclosures to IP54 (NEMA 3 Style), BS EN 60529

  Conformance:

Complies with BS EN 55022 and the relevant parts of BS EN 61000 series of standards

  CE Conformity:

CE Marked - being fully compliant with European Union Directives 2004/108/EC (replaced EMC Directive 89/336/EEC from July 2009) and 2006/95/EC (The Low Voltage Directive in force from January 2007)

  Warranty:

Two (2) Years / Twenty-Four (24) Months from date of supply.

Extendable, by purchasing an Extended Warranty, to Five (5) Years / Sixty (60 Months).

   Standard Features:

Input Circuit Breaker

Input Output Terminals

Bypass Control Switch

Voltmeter - Internal

  Optional Accessories:

Over / Low Voltage Protection

 

Ammeter

 

Output Breaker

 

No Volt Contacts

 

Inbuilt Manual Maintenance Bypass Switch

 

Lightning Surge Arrestors

 

Digital Power Metering - showing V, A, W, VA, AER, PF & KWH (with RS-482 Interface)

 

AquaStop Protective Coating - protection against damp and moisture ingress

IP 55 Ingress Protection

 

 

Please Note– These Stabilisers are not designed to support / protect voltage “back feed” applications, where energy is required to be also fed back into the utility supply.

Quick Finder




This website uses 'cookies' to give you the best, most relevant experience. Using this website means you’re OK with this. You can change which cookies are set at any time - and find out more about them - by following this link, or by clicking the cookie link at the bottom of any page.
This message will close within 20 seconds.

Accept all cookies