Three Phase Voltage Stabilizers 6 to 600 kVA

3 Wire (3 Phase + G/E – NO NEUTRAL)

With a fast speed of response and unparalleled inbuilt protection features, SES Three Phase Voltage Stabilizers deliver cost efficient voltage stabilisation, voltage surge and spike protection without compromising on technical performance or quality.

Features

 -

Step-Less Automatic Voltage Control

SES-3P-3W

 -

Wide range of permissible input voltage windows (±15% to ±40%)

 -

±1% Output Voltage Accuracy

 -

Inbuilt TVSS - Transient Voltage Surge & Spike Suppression

 -

Independent Phase Control

 -

High Overload Capability

 -

Over / Under Voltage Protection

 -

Phase Failure Protection

 -

Start Up Load Protection

 -

Front Panel Status Monitoring & Metering

 -

Input Circuit Breaker Protection fitted as Standard

 -

3 Years Standard Warranty

 -

Extremely Low Maintenance

 

 

To learn more please check-out the series listings below

 

The 3 Wire Ranges

SeriesVoltages

HD

International Voltages (380 - 415V)   

LD

US Voltages (190 - 220V)   

HD X468

US Voltages (440 - 480V)   

HLD

Step-Down Voltage Converter (Int to US)

LHD

Step-Up Voltage Converter (US to Int)

HLD X468

Step-Down Voltage Converter (US to US)

LHD X468

Step-Up Voltage Converter (US to US)


Also available as
4 Wire Solutions (3 Phase + Neutral + G/E)


Watch the Video

SES-3P-Video

 

 

Introduction

SES HD–3P Series - 6 to 600 kVA

3P 3W Solution

 

Input / Output: 380V, 400V &415V AC - 50 / 60Hz

 

Standard Permissible Input Voltage Window Options

SWING-SES-HD-3P-S

In situations where there is a reasonably good mains supply, a Stabiliser offering an input variation swing of ±15% (S15 Models) will usually be more than acceptable, but in more remote locations, or countries where the national supply infrastructure is less developed, variations of ±20% or greater may be needed to be accommodated by the Stabiliser.

TIP - The wider the permissible input voltage window you wish the Stabiliser to accomodate and the more accurate the voltage you require on the output, the more expensive the Stabiliser. So, when selecting the most appropriate and cost efficient model for your application, it pays to know the state of the utility mains supply on site and the designed input voltage tolerances of the load equipment you wish to protect.

 

PDF Data Sheets

General Series Data Sheet: pdf
Guide Specification: doc
Servo Electronic Overview Brochure: pdf

Get ADOBE READER  Get Adobe Flash Player

Model Ratings (kVA/Amps)

Model:

RATING

AMPS (Per Phase)

Dimensions

Weight

 

kVA

@380V

@400V

@415V

W x H x D(mm)

(Kgs)

SES-6HD-3P-S*

6

9.1

8.7

8.3

 

Dimensions, Weights and precise Standard and Optional Features as per the relevant S* model data sheet (see above) or upon request.

SES-10HD-3P-S*

10

15.2

14.4.

13.9

SES-15HD-3P-S*

15

22.8

21.6

20.9

SES-20HD-3P-S*

20

30.4

28.9

27.8

SES-25HD-3P-S*

25

38

36.1

35

SES-30HD-3P-S*

30

46

43

42

SES-35HD-3P-S*

35

53

51

49

SES-40HD-3P-S*

40

61

58

56

SES-45HD-3P-S*

45

68

65

63

SES-50HD-3P-S*

50

76

72

70

SES-55HD-3P-S*

55

84

79

77

SES-60HD-3P-S*

60

91

87

83

SES-75HD-3P-S*

75

114

108

104

SES-80HD-3P-S*

80

122

115

111

SES-90HD-3P-S*

90

137

130

125

SES-100HD-3P-S*

100

152

144

139

SES-120HD-3P-S*

120

182

173

167

SES-150HD-3P-S*

150

228

216

209

SES-180HD-3P-S*

180

273

260

250

SES-200HD-3P-S*

200

304

289

278

SES-250HD-3P-S*

250

380

361

348

SES-300HD-3P-S*

300

456

433

417

SES-350HD-3P-S*

350

532

505

487

SES-400HD-3P-S*

400

608

577

556

SES-450HD-3P-S*

450

684

649

626

SES-500HD-3P-S*

500

760

722

695

SES-600HD-3P-S*

600

911

866

835

S* = Selected permissible input voltage window - S15(±15%),S20(±20%),S25(±25%),S30 (±30%), S35(±35%) or S40(±40%)

 

Also available in / as

 

 

4 Wire Solution – With Neutral

IP54 / NEMA 3 Style Outdoor Enclosure

AC Power Line Conditioners

Technical Specification

Technology:

Servo Electronic- Variable Transformer controlled, series regulation transformer (buck-boast transformer with secondary wired in series with the load).

Input Voltage and permissible Input Voltage Window:

View

 

380V or 400V or 415V – Three Phase 3 Wire (3 Phase + G/E – NO Neutral)

With Output Voltage Accuracy

±1%

±3%

±5%

Ratings

*S15 Models– Input Window

± 15%

-17% /+18%

-19% /+21%

6 to 600 kVA

*S20Models– Input Window

± 20%

-22% / +23%

-24% / +26%

6 to 600 kVA

*S25Models– Input Window

± 25%

-27% / +28%

-29% / +31%

6 to 500 kVA

*S30Models– Input Window

± 30%

-32% / +33%

-34% / +36%

6 to 400 kVA

*S35Models– Input Window

± 35%

-37% / +38%

-39% / +41%

6 to 300 kVA

*S40Models– Input Window

± 40%

-42% / +43%

-44% / +46%

6 to 300 kVA

 

Output Voltage:

Presettable for any voltage between 380V, 400V or 415/V (Customer to Specify) – Three Phase 3 Wire (3 Phase + G/E – NO Neutral).

The permissible input voltage window is relative to the pre-set output voltage.

Output Voltage Accuracy:

± 1%, ± 3% or ± 5% - auto selection based on input voltage swing

Frequency:

47 to 65 Hz

Response Time:

< 1.5 ms

Correction Time:

A 10% supply variation will be corrected to within 2.5% in 0.6 seconds.

Efficiency:

98%

Power Factor:

Any Lagging to 0.95 leading

Surge Ratings:

10 x max current rating for 2 seconds

 

3 x max current rating for 1 minute

 

2 x max current rating for 5 minutes

Surge Suppression:

TVSS - Protects loads against high energy Spikes and Transient Voltages

Total Harmonic Distortion:

 < 1%

Independent Phase Control:             

Maintains each phase voltage stableirrespective of load unbalance, even up to 100% load unbalance.

Soft-Switch-On:

Ensures the output voltage is set to a minimum upon Switch-On before commencing stabilization - protects load equipment from damaging start-up voltage surges.

Environment:

Temperature Range -15°to 45° C

 

Derate by 2% for each additional °C up to max 60°C

 

Suitable for indoor tropical use 95% RH (non-condensing)

 

Maximum altitude 1000m. Derate by 2.5% for each additional 500m.

Paint Colour:

RAL 7032 (Grey - Powder Coat)

Construction:

Enclosures to IP20 (NEMA 1 Style), BS EN 60529

Conformance:

Complies with BS EN 55022 and the relevant parts of BS EN 61000 series of standards

 CE Conformity:

 

 

CE Marked - being fully compliant with European Union Directives 2004/108/EC (replaced EMC Directive 89/336/EEC from July 2009) and 2006/95/EC (The Low Voltage Directive in force from January 2007)

 Standard Warranty:

Three (3) Years / Thirty Six (36) Months from date of supply.

Extendable, by purchasing an Extended Warranty, to Five (5) Years / Sixty (60 Months).

 

Standard Features:

Input Circuit Breaker

Over/Low Voltage Protection

Phase Failure Protection

Bypass Control Switch

Voltmeter / Phase Selector Switch (internal)

 

Optional Accessories:

Output Circuit Breaker

Manual Maintenance Bypass Switch

Ammeter (with Phase Selector Switch)

Lightning Surge Arrestors

No Volt Remote Monitoring Contacts

Drip Proof Cowl for IP21 Ingress Protection

Digital Power Metering (with RS-485 interface)

- showing V, A, W, VA, AER, PF &kWH

Optional Step Down Voltage Feature:

Ideal for applications where the utility supply voltage is different from the load equipment’s requirement - see SES-HLD-3P SERIES Step Down AC Voltage Stabilisers TAB above.

Optional Isolation Transformer:

Shielded isolation transformer providing extra protection between the utility and the load. Protects against common and transverse mode electrical noise - see PCS-HD-3P SERIESAC Power Conditioners.

 

 

Please Note– These Stabilisers are not designed to support / protect voltage “back feed” applications, where energy is required to be also fed back into the utility supply.

Introduction

SES LD–3P Series - 6 to 400 kVA

3P 3W Solution

 

Input / Output: 190V, 200V, 208V, 220V&240V AC - 50 / 60Hz

 

Standard Permissible Input Voltage Window Options

SWING-SES-LD-3P-S

In situations where there is a reasonably good mains supply, a Stabiliser offering an input variation swing of ±15% (S15 Models) will usually be more than acceptable, but in more remote locations, or countries where the national supply infrastructure is less developed, variations of ±20% or greater may be needed to be accommodated by the Stabiliser.

TIP - The wider the permissible input voltage window you wish the Stabiliser to accomodate and the more accurate the voltage you require on the output, the more expensive the Stabiliser. So, when selecting the most appropriate and cost efficient model for your application, it pays to know the state of the utility mains supply on site and the designed input voltage tolerances of the load equipment you wish to protect.

 

PDF Data Sheets

General Series Data Sheet: pdf
Specific Input Voltage Swing Ranges:
S15 ±15% 6 to 400 kVA pdf
S20 ±20% 6 to 300 kVA pdf
S25 ±25% 6 to 250 kVA pdf
S30 ±30% 6 to 200 kVA pdf
S35 ±35% 6 to 120 kVA pdf
S40 ±40% 6 to 120 kVA pdf
All Input Voltage Swings pdf
Guide Specification: doc
Servo Electronic Overview Brochure: pdf

Get ADOBE READER  Get Adobe Flash Player

Model Ratings (kVA/Amps)

Model:

RATING

 

AMPS (Per Phase)

Dimensions

Weight

 

kVA

@190V

@200V

@208V

@220V

@240V

W x H x D(mm)

(Kgs)

SES-6LD-3P-S*

6

18

17

16

15

14

 

Dimensions, Weights and precise Standard and Optional Features as per the relevant S* model data sheet (see above) or upon request.

SES-10LD-3P-S*

10

30

28

27

26

24

SES-15LD-3P-S*

15

45

43

41

39

36

SES-20LD-3P-S*

20

60

57

55

52

48

SES-25LD-3P-S*

25

75

72

69

65

60

SES-30LD-3P-S*

30

91

86

83

78

72

SES-35LD-3P-S*

35

106

101

97

91

84

SES-40LD-3P-S*

40

121

115

111

104

96

SES-45LD-3P-S*

45

136

129

124

118

108

SES-50LD-3P-S*

50

151

144

138

131

120

SES-55LD-3P-S*

55

167

158

152

144

144

SES-60LD-3P-S*

60

182

173

166

157

132

SES-75LD-3P-S*

75

227

216

208

196

180

SES-80LD-3P-S*

80

243

230

222

209

192

SES-90LD-3P-S*

90

273

259

249

236

216

SES-100LD-3P-S*

100

303

288

277

262

240

SES-120LD-3P-S*

120

364

346

333

314

288

SES-150LD-3P-S*

150

456

432

416

393

360

SES-180LD-3P-S*

180

546

519

499

472

432

SES-200LD-3P-S*

200

607

577

555

524

481

SES-250LD-3P-S*

250

759

721

693

655

601

SES-300LD-3P-S*

300

911

865

832

787

721

SES-350LD-3P-S*

350

1063

1010

971

918

841

SES-400LD-3P-S*

400

1215

1154

1110

1049

962

S* = Selected permissible input voltage window - S15(±15%),S20(±20%),S25(±25%),S30 (±30%), S35(±35%) or S40(±40%)

 

Also available in / as

 

 

4 Wire Solution – With Neutral

IP54 / NEMA 3 Style Outdoor Enclosure

AC Power Line Conditioners

 

 

Technical Specification

Technology:

Servo Electronic- Variable Transformer controlled, series regulation transformer (buck-boast transformer with secondary wired in series with the load).

Input Voltage and permissible Input Voltage Window:

View

 

190V or 200V or 208V or 220V or 240V – Three Phase 4 Wire (3 Phase + G/E - NO Neutral)

With Output Voltage Accuracy

±1%

±3%

±5%

Ratings

*S15 Models– Input Window

± 15%

-17% /+18%

-19% /+21%

6 to 400 kVA

*S20Models– Input Window

± 20%

-22% / +23%

-24% / +26%

6 to 300 kVA

*S25Models– Input Window

± 25%

-27% / +28%

-29% / +31%

6 to 250 kVA

*S30Models– Input Window

± 30%

-32% / +33%

-34% / +36%

6 to 200 kVA

*S35Models– Input Window

± 35%

-37% / +38%

-39% / +41%

6 to 120 kVA

*S40Models– Input Window

± 40%

-42% / +43%

-44% / +46%

6 to 120 kVA

 

  Output Voltage:

190V or 200V or 208V or 220V or 240V(Customer to Specify) – Three Phase 4 Wire (3 Phase + G/E - NO Neutral).

The permissible input voltage window is relative to the pre-set output voltage.

  Output Voltage Accuracy:

± 1%, ± 3% or ± 5% - auto selection based on input voltage swing

  Frequency:

47 to 65 Hz

  Response Time:

< 1.5 ms

  Correction Time:

A 10% supply variation will be corrected to within 2.5% in 0.6 seconds.

  Efficiency:

98%

  Power Factor:

Any Lagging to 0.95 leading

  Surge Ratings:

10 x max current rating for 2 seconds

 

3 x max current rating for 1 minute

 

2 x max current rating for 5 minutes

  Surge Suppression:

TVSS - Protects loads against high energy Spikes and Transient Voltages

  Total Harmonic Distortion:

 < 1%

Independent Phase Control:             

Maintains each phase voltage stableirrespective of load unbalance, even up to 100% load unbalance.

  Soft-Switch-On:

Ensures the output voltage is set to a minimum upon Switch-On before commencing stabilization - protects load equipment from damaging start-up voltage surges.

  Environment:

Temperature Range -15°to 45° C

 

Derate by 2% for each additional °C up to max 60°C

 

Suitable for indoor tropical use 95% RH (non-condensing)

 

Maximum altitude 1000m. Derate by 2.5% for each additional 500m.

  Paint Colour:

RAL 7032 (Grey - Powder Coat)

  Construction:

Enclosures to IP20 (NEMA 1 Style), BS EN 60529

  Conformance:

Complies with BS EN 55022 and the relevant parts of BS EN 61000 series of standards

  CE Conformity:

 

 

CE Marked - being fully compliant with European Union Directives 2004/108/EC (replaced EMC Directive 89/336/EEC from July 2009) and 2006/95/EC (The Low Voltage Directive in force from January 2007)

 Standard Warranty:

Three (3) Years / Thirty Six (36) Months from date of supply.

Extendable, by purchasing an Extended Warranty, to Five (5) Years / Sixty (60 Months).

 

  Standard Features:

Input Circuit Breaker

Over/Low Voltage Protection

Phase Failure Protection

Bypass Control Switch

Voltmeter / Phase Selector Switch (internal)

 

Optional Accessories:

Output Circuit Breaker

Manual Maintenance Bypass Switch

Ammeter (with Phase Selector Switch)

Lightning Surge Arrestors

No Volt Remote Monitoring Contacts

Drip Proof Cowl for IP21 Ingress Protection

Digital Power Metering (with RS-485 interface)

- showing V, A, W, VA, AER, PF &kWH

Optional Step Up Voltage Feature:

Ideal for applications where the utility supply voltage is different from the load equipment’s requirement - see SES-LHD-3P SERIESor SES-LHD-3P-X468 SERIESStep Up AC Voltage Stabilisers TABs above.

Optional Isolation Transformer:

Shielded isolation transformer providing extra protection between the utility and the load. Protects against common and transverse mode electrical noise - see PCS-LD-3P SERIESAC Power Conditioners.

 

 

Please Note– These Stabilisers are not designed to support / protect voltage “back feed” applications, where energy is required to be also fed back into the utility supply.

Introduction

SES HD–3P X468 Series - 6 to 600 kVA

3P 3W Solution

 

Input / Output: 440V, 460V & 480V AC - 50 / 60Hz

 

Standard Permissible Input Voltage Window Options

SWING-SES-HD-3P-S

In situations where there is a reasonably good mains supply, a Stabiliser offering an input variation swing of ±15% (S15 Models) will usually be more than acceptable, but in more remote locations, or countries where the national supply infrastructure is less developed, variations of ±20% or greater may be needed to be accommodated by the Stabiliser.

TIP - The wider the permissible input voltage window you wish the Stabiliser to accomodate and the more accurate the voltage you require on the output, the more expensive the Stabiliser. So, when selecting the most appropriate and cost efficient model for your application, it pays to know the state of the utility mains supply on site and the designed input voltage tolerances of the load equipment you wish to protect.

 
 

PDF Data Sheets

General Series Data Sheet: pdf
Guide Specification: doc
Servo Electronic Overview Brochure: pdf

Get ADOBE READER  Get Adobe Flash Player

Model Ratings (kVA/Amps)

Model:

RATING

AMPS (Per Phase)

Dimensions

Weight

 

kVA

@440V

@460V

@480V

W x H x D(mm)

(Kgs)

SES-6HD-3P-S*-X468

6

7.9

7.5

7.2

 

Dimensions, Weights and precise Standard and Optional Features as per the relevant S* model data sheet (see above) or upon request.

SES-10HD-3P-S*-X468

10

13.1

12.5

12.0

SES-15HD-3P-S*-X468

15

19.7

18.8

18.0

SES-20HD-3P-S*-X468

20

26.2

25.1

24.0

SES-25HD-3P-S*-X468

25

32

31

30

SES-30HD-3P-S*-X468

30

39

37

36

SES-35HD-3P-S*-X468

35

45

43

42

SES-40HD-3P-S*-X468

40

52

50

48

SES-45HD-3P-S*-X468

45

59

56

54

SES-50HD-3P-S*-X468

50

65

62

60

SES-55HD-3P-S*-X468

55

72

69

66

SES-60HD-3P-S*-X468

60

78

75

72

SES-75HD-3P-S*-X468

75

98

94

90

SES-80HD-3P-S*-X468

80

104

100

96

SES-90HD-3P-S*-X468

90

118

112

108

SES-100HD-3P-S*-X468

100

131

125

120

SES-120HD-3P-S*-X468

120

157

150

144

SES-150HD-3P-S*-X468

150

196

188

180

SES-180HD-3P-S*-X468

180

236

225

216

SES-200HD-3P-S*-X468

200

262

251

240

SES-250HD-3P-S*-X468

250

327

313

300

SES-300HD-3P-S*-X468

300

393

376

360

SES-350HD-3P-S*-X468

350

459

439

420

SES-400HD-3P-S*-X468

400

524

501

481

SES-450HD-3P-S*-X468

450

590

564

541

SES-500HD-3P-S*-X468

500

655

627

601

SES-600HD-3P-S*-X468

600

787

752

721

S* = Selected permissible input voltage window - S15(±15%),S20(±20%),S25(±25%),S30 (±30%), S35(±35%) or S40(±40%)

 

Also available in / as

 

 

4 Wire Solution – With Neutral

IP54 / NEMA 3 Style Outdoor Enclosure

AC Power Line Conditioners

 

 

Technical Specification

Technology:

Servo Electronic- Variable Transformer controlled, series regulation transformer (buck-boast transformer with secondary wired in series with the load).

Input Voltage and permissible Input Voltage Window:

View

 

440V or 460V or 480V – Three Phase 3 Wire (3 Phase + G/E – NO Neutral)

With Output Voltage Accuracy

±1%

±3%

±5%

Ratings

*S15 Models– Input Window

± 15%

-17% /+18%

-19% /+21%

6 to 600 kVA

*S20Models– Input Window

± 20%

-22% / +23%

-24% / +26%

6 to 600 kVA

*S25Models– Input Window

± 25%

-27% / +28%

-29% / +31%

6 to 500 kVA

*S30Models– Input Window

± 30%

-32% / +33%

-34% / +36%

6 to 400 kVA

*S35Models– Input Window

± 35%

-37% / +38%

-39% / +41%

6 to 300 kVA

*S40Models– Input Window

± 40%

-42% / +43%

-44% / +46%

6 to 300 kVA

 

  Output Voltage:

440V or 460V or 480V(Customer to Specify)– Three Phase 3 Wire (3 Phase + G/E – NO Neutral).

The permissible input voltage window is relative to the pre-set output voltage.

  Output Voltage Accuracy:

± 1%, ± 3% or ± 5% - auto selection based on input voltage swing

  Frequency:

47 to 65 Hz

  Response Time:

< 1.5 ms

  Correction Time:

A 10% supply variation will be corrected to within 2.5% in 0.6 seconds.

  Efficiency:

98%

  Power Factor:

Any Lagging to 0.95 leading

  Surge Ratings:

10 x max current rating for 2 seconds

 

3 x max current rating for 1 minute

 

2 x max current rating for 5 minutes

  Surge Suppression:

TVSS - Protects loads against high energy Spikes and Transient Voltages

  Total Harmonic Distortion:

 < 1%

Independent Phase Control:             

Maintains each phase voltage stableirrespective of load unbalance, even up to 100% load unbalance.

  Soft-Switch-On:

Ensures the output voltage is set to a minimum upon Switch-On before commencing stabilization - protects load equipment from damaging start-up voltage surges.

  Environment:

Temperature Range -15°to 45° C

 

Derate by 2% for each additional °C up to max 60°C

 

Suitable for indoor tropical use 95% RH (non-condensing)

 

Maximum altitude 1000m. Derate by 2.5% for each additional 500m.

  Paint Colour:

RAL 7032 (Grey - Powder Coat)

  Construction:

Enclosures to IP20 (NEMA 1 Style), BS EN 60529

  Conformance:

Complies with BS EN 55022 and the relevant parts of BS EN 61000 series of standards

  CE Conformity:

 

 

CE Marked - being fully compliant with European Union Directives 2004/108/EC (replaced EMC Directive 89/336/EEC from July 2009) and 2006/95/EC (The Low Voltage Directive in force from January 2007)

 Standard Warranty:

Three (3) Years / Thirty Six (36) Months from date of supply.

Extendable, by purchasing an Extended Warranty, to Five (5) Years / Sixty (60 Months).

 

  Standard Features:

Input Circuit Breaker

Over/Low Voltage Protection

Phase Failure Protection

Bypass Control Switch

Voltmeter / Phase Selector Switch (internal)

 

Optional Accessories:

Output Circuit Breaker

Manual Maintenance Bypass Switch

Ammeter (with Phase Selector Switch)

Lightning Surge Arrestors

No Volt Remote Monitoring Contacts

Drip Proof Cowl for IP21 Ingress Protection

Digital Power Metering (with RS-485 interface)

- showing V, A, W, VA, AER, PF &kWH

Optional Step Down Voltage Feature:

Ideal for applications where the utility supply voltage is different from the load equipment’s requirement - see SES-HLD-3P-X468 SERIES Step Down AC Voltage Stabilisers TAB above.

Optional Isolation Transformer:

Shielded isolation transformer providing extra protection between the utility and the load. Protects against common and transverse mode electrical noise - see PCS-HD-3P-X468 SERIESAC Power Conditioners.

 

 

Please Note – These Stabilisers are not designed to support / protect voltage “back feed” applications, where energy is required to be also fed back into the utility supply.

Introduction

SES HLD–3P Series - 6 to 1200 kVA

3P 3W Solution

 

Input: 380V, 400V &415V AC - 50 / 60Hz
Output: 190V, 200V, 208V,220V or 240V AC - 50 / 60Hz

 

Standard Permissible Input Voltage Window Options

SWING-SES-HLD-3P-S

In situations where there is a reasonably good mains supply, a Stabiliser offering an input variation swing of ±15% (S15 Models) will usually be more than acceptable, but in more remote locations, or countries where the national supply infrastructure is less developed, variations of ±20% or greater may be needed to be accommodated by the Stabiliser.

TIP - The wider the permissible input voltage window you wish the Stabiliser to accomodate and the more accurate the voltage you require on the output, the more expensive the Stabiliser. So, when selecting the most appropriate and cost efficient model for your application, it pays to know the state of the utility mains supply on site and the designed input voltage tolerances of the load equipment you wish to protect.

 
 

PDF Data Sheets

General Series Data Sheet: pdf
Guide Specification: doc
Servo Electronic Overview Brochure: pdf

Get ADOBE READER  Get Adobe Flash Player

Model Ratings (kVA/Amps

Model:

RATING

 

AMPS (Per Phase)

Dimensions

Weight

 

kVA

@190V

@200V

@208V

@220V

@240V

W x H x D(mm)

(Kgs)

SES-6HLD-3P-S*

6

18

17

16

15

14

 

Dimensions, Weights and precise Standard and Optional Features as per the relevant S* model data sheet (see above) or upon request.

 

 

 

 

 

 

NB:FREQUENCY CONVERSION- Where Frequency Conversion  is also required a separate standalone Frequency Converter will be required.

SES-10HLD-3P-S*

10

30

28

27

26

24

SES-15HLD-3P-S*

15

45

43

41

39

36

SES-20HLD-3P-S*

20

60

57

55

52

48

SES-25HLD-3P-S*

25

75

72

69

65

60

SES-30HLD-3P-S*

30

91

86

83

78

72

SES-35HLD-3P-S*

35

106

101

97

91

84

SES-40HLD-3P-S*

40

121

115

111

104

96

SES-45HLD-3P-S*

45

136

129

124

118

108

SES-50HLD-3P-S*

50

151

144

138

131

120

SES-55HLD-3P-S*

55

167

158

152

144

144

SES-60HLD-3P-S*

60

182

173

166

157

132

SES-75HLD-3P-S*

75

227

216

208

196

180

SES-80HLD-3P-S*

80

243

230

222

209

192

SES-90HLD-3P-S*

90

273

259

249

236

216

SES-100HLD-3P-S*

100

303

288

277

262